Evidence map›Paper›PMID 35208101›Full record

ArticleMaterials (Basel, Switzerland)2022

Corrosion Behavior of Titanium Dental Implants with Implantoplasty.

Pablo Lozano, Marta Peña, Mariano Herrero-Climent, Jose Vicente Rios-Santos, Blanca Rios-Carrasco, Aritza Brizuela, Javier Gil

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Electrical Potentiometry with Intraoral Applications.Materials (Basel, Switzerland) · 2022
    Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Pablo LozanoDepartment of Periodontology, Dental School, University of Seville, 41009 Seville, Spain.
Marta PeñaDepartment of Periodontology, Dental School, University of Seville, 41009 Seville, Spain.
Mariano Herrero-ClimentDepartment of Periodontology, Porto Dental Institute, 4150-518 Porto, Portugal.ORCID 0000-0003-3284-1528
Jose Vicente Rios-SantosDepartment of Periodontology, Dental School, University of Seville, 41009 Seville, Spain.ORCID 0000-0002-8121-6166
Blanca Rios-CarrascoDepartment of Periodontology, Dental School, University of Seville, 41009 Seville, Spain.ORCID 0000-0002-2832-5902
Aritza BrizuelaDepartamento de Cirugía y Especialidades Médico-Quirúrgicas, Universidad de Oviedo, 33006 Oviedo, Spain.ORCID 0000-0001-6421-3863
Javier GilBioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, Sant Cugat del Vallés, 08195 Barcelona, Spain.ORCID 0000-0002-6824-1412
Universidad de Sevilla · ESUniversidad de Oviedo · ESUniversitat Internacional de Catalunya · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol. Using X-ray diffraction, we determined the stresses accumulated in each of the as-received, machined and debris implants. The resistance to corrosion in open circuit and potentiodynamically in physiological medium has been determined, and the corrosion potentials and intensities have been determined. Tests have been carried out to determine ion release by ICP-MS at different immersion times. The results show that the corrosion resistance and the release of titanium ions into the medium are related to the accumulated energy or the degree of deformation. The titanium debris exhibit compressive residual stresses of -202 MPa, the implant treated with implantoplasty -120 MPa, and as-received -77 MPa, with their corrosion behavior resulting in corrosion rates of 0.501, 0.77, and 0.444 mm/year, respectively. Debris is the material with the worst corrosion resistance and the one that releases the most titanium ions to the physiological medium (15.3 ppb after 21 days vs. 7 ppb for as-received samples). Pitting has been observed on the surface of the debris released into the physiological environment. This behavior should be taken into account by clinicians for the good long-term behavior of implants with implantoplasty.

Indexed as

corrosiondebrisimplantoplastyresidual stressestitanium ion release

Identifiers

PMID35208101
PMCPMC8875252
OpenAlexW4214718321

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.