ArticleMaterials (Basel, Switzerland)2022
Comparative Performance Evaluation of Multiconfiguration Touch-Trigger Probes for Closed-Loop Machining of Large Jet Engine Cases.
Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Measurement of the Pitch Diameter of Buttress Threads Using a Touch-Trigger Probe on a CNC Machine Tool.Materials (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This article presents advances in the methodology of rapid various probe configurations comparison for the five-axis, tilting-head machine tools in conjunction with master artifacts. The research was performed in a direct context of automated machining of large, complex jet engine cases made from 17-4PH and 321 stainless steel materials. The aim of the study was to investigate whether all probe configurations have comparable measurement capability for use in manufacturing environment conditions. Based on the preliminary stage of the study, the T1 main straight probe achieved acceptable results of repeatability and reproducibility, lower than 10%, except for the reference diameter measurement of MT#2, where 15.4% R&R was achieved, conditionally accepted. For the straight probe configuration, error lower than 10 μm was achieved for the true position measurement and error ±10 μm for the reference diameter measurement, in relation to the vertical and horizontal head position, with the exception of the T9 and T5 MT#2 probe configuration, where higher error was noticed. The obtained results of the T5 MT#2 and T9 probes were supplemented with additional tests, which are also included. For the custom styli probes, the T4 and T6 configurations, unacceptable error, higher than 0.30 mm, was observed for the
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.