Evidence map›Paper›PMID 35207971›Full record

ArticleMaterials (Basel, Switzerland)2022

Tribocorrosion Susceptibility and Mechanical Characteristics of As-Received and Long-Term In-Vivo Aged Nickel-Titanium and Stainless-Steel Archwires.

Jasmina Primozic, Miha Hren, Uros Mezeg, Andraz Legat

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.7field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Effect of use of antiseptics and fluorides during orthodontic treatment on working properties of NiTi archwires in levelling dental arches : A randomized controlled trial.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2024
    Trial
  2. Review
  3. Review
  4. Article
  5. Review
  6. Bioactive Dental Materials: The Current Status.Materials (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Jasmina PrimozicFaculty of Medicine, University of Ljubljana, SI-1000 Ljubljana, Slovenia.ORCID 0000-0002-2421-8886
Miha HrenSlovenian National Building and Civil Engineering Institute, SI-1000 Ljubljana, Slovenia.ORCID 0000-0001-5826-0508
Uros MezegFaculty of Medicine, University of Ljubljana, SI-1000 Ljubljana, Slovenia.
Andraz LegatSlovenian National Building and Civil Engineering Institute, SI-1000 Ljubljana, Slovenia.
Slovenian National Building and Civil Engineering Institute · SIUniversity of Ljubljana · SI

Funding

Slovenian Research Agency P3-0374, P2-0273, J3-2520, L3-5501
6 · The paper itself

Abstract

To evaluate the effect of long-term in-vivo aging on orthodontic archwires, we aimed to assess the triboelectrochemical and mechanical characteristics of as-received and in-vivo aged nickel-titanium (NiTi) and stainless-steel (SS) orthodontic archwires. Four consecutive tribocorrosion cycles on six NiTi and six SS archwires, as-received and in-vivo aged, were performed on a reciprocal tribometer. Electrochemical noise and friction coefficient measurements, three-dimensional surface profiling, and hardness measurements were performed. Repassivation times of as-received archwires were longer than of the in-vivo aged; however, were shorter for NiTi. Friction coefficients were higher for NiTi than for SS archwires. Sudden major current drops concomitant with inverse potential shifts and friction coefficients' fluctuations, were seen for as-received (last cycle) and in-vivo aged (last three cycles) NiTi archwires. More pronounced tribocorrosion damage was observed on in-vivo aged NiTi than on other archwires. Hardness was generally higher inside the wear track of archwires. Long-term in-vivo exposure decreases the corrosion susceptibility of archwires, more evidently for the NiTi ones. Sudden major fluctuations in electrochemical current, potential, and friction coefficient detected for NiTi archwires, might be related to localized residual parts of the oxide layer persisting due to increased surface roughness or to phase transformations of the alloy's crystal structure.

Indexed as

electrochemical noiseorthodontic archwirestribocorrosion

Identifiers

PMID35207971
PMCPMC8876863
OpenAlexW4213247323

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.