Evidence map›Paper›PMID 35207635›Full record

ArticleJournal of personalized medicine2022

Extrafine Beclometasone Dipropionate/Formoterol NEXThaler on Device Usability, Adherence, Asthma Control and Quality of Life. A Panhellenic Prospective, Non-Interventional Observational Study in Patients with Asthma-The NEXT-Step Study.

Petros Bakakos, Panagiotis Chatziapostolou, Panos Katerelos, Petros Efstathopoulos, Aliki Korkontzelou, Paraskevi Katsaounou

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. NEXThalerJournal of clinical medicine · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Petros Bakakos1st University Department of Respiratory Medicine, Medical School, National and Kapodistrian University of Athens, "Sotiria" Chest Diseases Hospital, 11527 Athens, Greece.ORCID 0000-0001-9256-9656
Panagiotis ChatziapostolouPulmonary Clinic, Euromedica General Clinic of Thessaloniki, 54645 Thessaloniki, Greece.
Panos KaterelosBioStatistics PC, 11474 Athens, Greece.
Petros EfstathopoulosChiesi Hellas S.A., 17455 Alimos, Greece.
Aliki KorkontzelouChiesi Hellas S.A., 17455 Alimos, Greece.
Paraskevi KatsaounouPulmonary and Respiratory Failure Department, First ICU, Evangelismos Hospital, 10676 Athens, Greece.ORCID 0000-0002-8736-619X
Space Hellas (Greece) · GREuromedica · GREvangelismos Hospital · GRNational and Kapodistrian University of Athens · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe fixed combination of extrafine beclometasone dipropionate 100 μg/formoterol 6 μg (extrafine BDP/F) delivered by NEXThaler has proved to be effective in patients with moderate-to-severe asthma in terms of lung function, symptoms and asthma control. The aim of this study was to investigate the usability/satisfaction of NEXThaler and adherence to treatment in asthma patients not well controlled by low-dose inhaled corticosteroids (ICS).

methodsThis was a 6-month prospective, multicenter, open-label, observational study in 661 patients with asthma not well controlled by low-dose ICS according to the physician's clinical assessment, which have received regular treatment with extrafine BDP/F NEXThaler. Feeling of Satisfaction with Inhaler (FSI), treatment adherence with self-reported Morisky scale, asthma control, lung function and QoL were recorded at baseline, 3 and 6 months after treatment with extrafine BDP/F.

resultsThe percentage of patients at least "fairly" satisfied with NEXThaler usability (FSI-10 score 40 to 50) was 96.3%. The mean FSI-10 total score was 46.8 ± 4.4 on Visit 2 and increased to 48.1 ± 3.3 on Visit 3 (

conclusionsThe NEXThaler device, delivering a combination of BDP/F, achieves satisfaction and high adherence in patients with asthma not well controlled with low-dose ICS. Asthma control, QoL, lung function and rescue medication use were improved in a Greek real-world setting.

Indexed as

adherenceasthmaBDP/Fextrafineinhalation deviceNEXThalerquality of lifesatisfactionusability

Identifiers

PMID35207635
PMCPMC8876660
OpenAlexW4206959204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.