Evidence map›Paper›PMID 35206798›Full record

ReviewHealthcare (Basel, Switzerland)2022

Patient Ability to Use Old versus New/Modified Model Adrenaline Autoinjection Emergency Medical Devices for Anaphylaxis in Prehospital Setting: A Systematic Review and Meta-Analysis.

Leong Chow Wei, Mohd Boniami Yazid, Mohd Noor Norhayati, Abu Yazid Md Noh, Andey Rahman

Open access · goldAbstract readReview
In one paragraph

Review in Healthcare (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 59% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Leong Chow WeiDepartment of Emergency Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia.ORCID 0000-0003-1293-2262
Mohd Boniami YazidDepartment of Emergency Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia.ORCID 0000-0003-1177-7264
Mohd Noor NorhayatiDepartment of Family Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia.ORCID 0000-0002-6372-1476
Abu Yazid Md NohDepartment of Emergency Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia.ORCID 0000-0002-8127-7647
Andey RahmanDepartment of Emergency Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia.
Hospital Universiti Sains Malaysia · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe goal of this study was to determine the individual's ability to use new/modified model AAI compared to old model AAIs devices for anaphylaxis.

methodsThe protocol was established a priori and published on PROSPERO (CRD42021229691) and was conducted based on PRISMA guidelines. MEDLINE and CENTRAL were searched until 31 January 2021. Only RCTs were included in this review. Primary studies comparing old model AAI to new/modified model AAI emergency medical devices were included. Primary outcomes included number of successful administrations, and number of individuals to complete all steps. Secondary outcomes included successful removal of device safety guards, placement of correct end of the device against the thigh and holding of the device in place for adequate time after administration; the frequency of an adverse event (digital injection); individual preferences in terms of size, individual preference in terms of ease for carrying, overall patient preference; and the mean time of delivery.

resultsOverall, seven trials consisting of 1359 patients were analyzed. Reporting of adverse events was limited to digital injection, which was significantly higher in the old model AAI (RR 6.90, 95% CI 3.27 to 14.57; I2 statistic = 0%;

conclusionsWe cannot make any new recommendations on the effectiveness of different models of AAIs regarding successful administration. However, considering the aspect of safety, we think that mew/modified model AAI can be chosen as the old model AAI was associated with a higher frequency of the adverse event (digital injection).

Indexed as

AAIadrenalineanaphylaxis

Identifiers

PMID35206798
PMCPMC8872424
OpenAlexW4205862163

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.