Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla.

Mariya S Pravdivtseva, Franziska Gaidzik, Philipp Berg, Patricia Ulloa, Naomi Larsen, Olav Jansen, Jan-Bernd Hövener, Mona Salehi Ravesh

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Mariya S PravdivtsevaDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany.ORCID 0000-0001-9442-088X
Franziska GaidzikDepartment of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany.
Philipp BergDepartment of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany.
Patricia UlloaDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany.
Naomi LarsenDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany.
Olav JansenDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany.
Jan-Bernd HövenerDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany.
Mona Salehi RaveshDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany.ORCID 0000-0003-2636-7508
Christian-Albrechts-Universität zu Kiel · DEUniversity Hospital Magdeburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels-non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically. Here, we investigated the effect of spatial resolution and CS acceleration on flow measurements by using 4D flow MRI in small vessels in vitro at 3 T. We compared the flow in silicon tubes (inner diameters of 2, 3, 4, and 5 mm) measured with 4D flow MRI, accelerated with four CS factors (CS = 2.5, 4.5, 6.5, and 13) and three voxel sizes (0.5, 1, and 1.5 mm

Indexed as

AneurysmMagnetic Resonance ImagingAccelerationBlood Flow VelocityHumansHydrodynamics4D flow MRIcompressed sensingflowintracranial aneurysmintracranial vesselspartial volume effect

Identifiers

PMID35202203
PMCPMC8880336
OpenAlexW4211075104

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.