Evidence map›Paper›PMID 35200379›Full record

ArticleBiosensors2022

Haemoprocessor: A Portable Platform Using Rapid Acoustically Driven Plasma Separation Validated by Infrared Spectroscopy for Point-of-Care Diagnostics.

Kamal Prakash Prasanna Ravindran Nair, Thulya Chakkumpulakkal Puthan Veettil, Bayden R Wood, Debjani Paul, Tuncay Alan

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Kamal Prakash Prasanna Ravindran NairDepartment of Mechanical & Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia.ORCID 0000-0002-6728-1658
Thulya Chakkumpulakkal Puthan VeettilMonash Centre for Biospectroscopy, Department of Chemistry, Monash University, Melbourne, VIC 3800, Australia.ORCID 0000-0002-6234-754X
Bayden R WoodMonash Centre for Biospectroscopy, Department of Chemistry, Monash University, Melbourne, VIC 3800, Australia.
Debjani PaulDepartment of Biosciences & Bioengineering, Indian Institute of Technology Bombay, Mumbai 400076, India.ORCID 0000-0001-9281-3516
Tuncay AlanDepartment of Mechanical & Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia.
Indian Institute of Technology Bombay · INMonash University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The identification of biomarkers from blood plasma is at the heart of many diagnostic tests. These tests often need to be conducted frequently and quickly, but the logistics of sample collection and processing not only delays the test result, but also puts a strain on the healthcare system due to the sheer volume of tests that need to be performed. The advent of microfluidics has made the processing of samples quick and reliable, with little or no skill required on the user's part. However, while several microfluidic devices have been demonstrated for plasma separation, none of them have validated the chemical integrity of the sample post-process. Here, we present Haemoprocessor: a portable, robust, open-fluidic system that utilizes Travelling Surface Acoustic Waves (TSAW) with the expression of overtones to separate plasma from 20× diluted human blood within a span of 2 min to achieve 98% RBC removal. The plasma and red blood cell separation quality/integrity was validated through Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy and multivariate analyses to ascertain device performance and reproducibility when compared to centrifugation (the prevailing gold-standard for plasma separation). Principal Component Analysis (PCA) showed a remarkable separation of 92.21% between RBCs and plasma components obtained through both centrifugation and Haemoprocessor methods. Moreover, a close association between plasma isolates acquired by both approaches in PCA validated the potential of the proposed system as an eminent cell enrichment and plasma separation platform. Thus, compared to contemporary acoustic devices, this system combines the ease of operation, low sample requirement of an open system, the versatility of a SAW device using harmonics, and portability.

Indexed as

MicrofluidicsPlasmaHumansPoint-of-Care TestingReproducibility of ResultsSpectroscopy, Fourier Transform InfraredATR-FTIR spectroscopyharmonic interdigitated transducersopen microfluidicsparticle sortingplasma separationpoint-of-care diagnosticssurface acoustic waves

Identifiers

PMID35200379
PMCPMC8924765
OpenAlexW4213329823

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.