ArticleBiosensors2022
Silicon Nanowires Length and Numbers Dependence on Sensitivity of the Field-Effect Transistor Sensor for Hepatitis B Virus Surface Antigen Detection.
Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 13 citations in OpenAlex.
- Review
- Implantable pH Sensing System Using Vertically Stacked Silicon Nanowire Arrays and Body Channel Communication for Gastroesophageal Reflux Monitoring.Sensors (Basel, Switzerland) · 2024Article
- Nanoribbon Biosensor-Based Detection of microRNA Markers of Prostate Cancer.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
Silicon nanowire field effect transistor (NWFET) sensors have been demonstrated to have high sensitivity, are label free, and offer specific detection. This study explored the effect of nanowire dimensions on sensors' sensitivity. We used sidewall spacer etching to fabricate polycrystalline silicon NWFET sensors. This method does not require expensive nanoscale exposure systems and reduces fabrication costs. We designed transistor sensors with nanowires of various lengths and numbers. Hepatitis B surface antigen (HBsAg) was used as the sensing target to explore the relationships of nanowire length and number with biomolecule detection. The experimental results revealed that the sensor with a 3 µm nanowire exhibited high sensitivity in detecting low concentrations of HBsAg. However, the sensor reached saturation when the biomolecule concentration exceeded 800 fg/mL. Sensors with 1.6 and 5 µm nanowires exhibited favorable linear sensing ranges at concentrations from 800 ag/mL to 800 pg/mL. The results regarding the number of nanowires revealed that the use of few nanowires in transistor sensors increases sensitivity. The results demonstrate the effects of nanowire dimensions on the silicon NWFET biosensors.