Evidence map›Paper›PMID 35200338›Full record

ArticleBiosensors2022

Graphene Quantum Dots-Based Electrochemical Biosensing Platform for Early Detection of Acute Myocardial Infarction.

Tanveer A Tabish, Hasan Hayat, Aumber Abbas, Roger J Narayan

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
6.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it, 72 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Review
  6. Multifunctional Conductive Nanofibers for Self-Powered Glucose Biosensors.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Review
  16. Nanomedicines for cardiovascular disease.Nature cardiovascular research · 2023
    Review
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 2 countries.

Tanveer A TabishDepartment of Materials and London Centre for Nanotechnology, Imperial College London, London SW7 2AZ, UK.ORCID 0000-0001-5578-076X
Hasan HayatCollege of Engineering, Swansea University, Wales SA1 8EN, UK.
Aumber AbbasSchool of Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU, UK.
Roger J NarayanJoint Department of Biomedical Engineering, North Carolina and North Carolina State University, Raleigh, NC 27695-7907, USA.ORCID 0000-0002-4876-9869
London Centre for Nanotechnology · GBNewcastle University · GBNorth Carolina State University · USSwansea University · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart failure resulting from acute myocardial infarction (AMI) is an important global health problem. Treatments of heart failure and AMI have improved significantly over the past two decades; however, the available diagnostic tests only give limited insights into these heterogeneous conditions at a reversible stage and are not precise enough to evaluate the status of the tissue at high risk. Innovative diagnostic tools for more accurate, more reliable, and early diagnosis of AMI are urgently needed. A promising solution is the timely identification of prognostic biomarkers, which is crucial for patients with AMI, as myocardial dysfunction and infarction lead to more severe and irreversible changes in the cardiovascular system over time. The currently available biomarkers for AMI detection include cardiac troponin I (cTnI), cardiac troponin T (cTnT), myoglobin, lactate dehydrogenase, C-reactive protein, and creatine kinase and myoglobin. Most recently, electrochemical biosensing technologies coupled with graphene quantum dots (GQDs) have emerged as a promising platform for the identification of troponin and myoglobin. The results suggest that GQDs-integrated electrochemical biosensors can provide useful prognostic information about AMI at an early, reversible, and potentially curable stage. GQDs offer several advantages over other nanomaterials that are used for the electrochemical detection of AMI such as strong interactions between cTnI and GQDs, low biomarker consumption, and reusability of the electrode; graphene-modified electrodes demonstrate excellent electrochemical responses due to the conductive nature of graphene and other features of GQDs (e.g., high specific surface area, π-π interactions with the analyte, facile electron-transfer mechanisms, size-dependent optical features, interplay between bandgap and photoluminescence, electrochemical luminescence emission capability, biocompatibility, and ease of functionalization). Other advantages include the presence of functional groups such as hydroxyl, carboxyl, carbonyl, and epoxide groups, which enhance the solubility and dispersibility of GQDs in a wide variety of solvents and biological media. In this perspective article, we consider the emerging knowledge regarding the early detection of AMI using GQDs-based electrochemical sensors and address the potential role of this sensing technology which might lead to more efficient care of patients with AMI.

Indexed as

Biosensing TechniquesGraphiteMyocardial InfarctionQuantum DotsEarly DiagnosisHumansGraphitebiosensingelectrochemicalgraphene quantum dotsmyocardial infarction

Identifiers

PMID35200338
PMCPMC8869523
OpenAlexW4210309787

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.