ArticleJournal of biomedical optics2022
Development of a Monte Carlo-wave model to simulate time domain diffuse correlation spectroscopy measurements from first principles.
Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 21 citations in OpenAlex.
- Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements.Neurophotonics · 2026Article
- Approaches for modelling autocorrelation function and data processing in time-domain diffuse correlation spectroscopy.Biomedical optics express · 2025Article
- Comparison of diffuse correlation spectroscopy analytical models for cerebral blood flow measurements.Journal of biomedical optics · 2025Article
- Cerebral blood flow monitoring using a deep learning implementation of the two-layer diffuse correlation spectroscopy analytical model with a 512 × 512 SPAD array.Neurophotonics · 2025Article
- Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery.Biomedical optics express · 2024Article
- Comprehensive workflow and its validation for simulating diffuse speckle statistics for optical blood flow measurements.Biomedical optics express · 2024Article
- Quantification of blood flow index in diffuse correlation spectroscopy using a robust deep learning method.Journal of biomedical optics · 2024Article
- scatterBrains: an open database of human head models and companion optode locations for realistic Monte Carlo photon simulations.Journal of biomedical optics · 2023Article
- Massively parallel, real-time multispeckle diffuse correlation spectroscopy using a 500 × 500 SPAD camera.Biomedical optics express · 2023Article
- Interferometric diffusing wave spectroscopy imaging with an electronically variable time-of-flight filter.Optica · 2023Article
- Numerical approach to quantify depth-dependent blood flow changes in real-time using the diffusion equation with continuous-wave and time-domain diffuse correlation spectroscopy.Biomedical optics express · 2023Article
- Laser speckle simulation tool based on stochastic differential equations for bio imaging applications.Biomedical optics express · 2022Article
- Model of dynamic speckle evolution for evaluating laser speckle contrast measurements of tissue dynamics.Biomedical optics express · 2022Article
- Special Section Guest Editorial: Introduction to the Special Section Celebrating 30 years of Open Source Monte Carlo Codes in Biomedical Optics.Journal of biomedical optics · 2022Article
- Effects of aerobic exercise on cognitive function in adults with major depressive disorder: A systematic review and meta-analysis.International journal of clinical and health psychology : IJCHPArticle
- Validation of the Linearity in Image Reconstruction Methods for Speckle Contrast Optical Tomography.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics SocietyArticle
- Pathlength-selective, interferometric diffuse correlation spectroscopy.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
significanceDiffuse correlation spectroscopy (DCS) is an optical technique that measures blood flow non-invasively and continuously. The time-domain (TD) variant of DCS, namely, TD-DCS has demonstrated a potential to improve brain depth sensitivity and to distinguish superficial from deeper blood flow by utilizing pulsed laser sources and a gating strategy to select photons with different pathlengths within the scattering tissue using a single source-detector separation. A quantitative tool to predict the performance of TD-DCS that can be compared with traditional continuous wave DCS (CW-DCS) currently does not exist but is crucial to provide guidance for the continued development and application of these DCS systems.
aimsWe aim to establish a model to simulate TD-DCS measurements from first principles, which enables analysis of the impact of measurement noise that can be utilized to quantify the performance for any particular TD-DCS system and measurement geometry. APPROACH: We have integrated the Monte Carlo simulation describing photon scattering in biological tissue with the wave model that calculates the speckle intensity fluctuations due to tissue dynamics to simulate TD-DCS measurements from first principles.
resultsOur model is capable of simulating photon counts received at the detector as a function of time for both CW-DCS and TD-DCS measurements. The effects of the laser coherence, instrument response function, detector gate delay, gate width, intrinsic noise arising from speckle statistics, and shot noise are incorporated in the model. We have demonstrated the ability of our model to simulate TD-DCS measurements under different conditions, and the use of our model to compare the performance of TD-DCS and CW-DCS under a few typical measurement conditions.
conclusionWe have established a Monte Carlo-Wave model that is capable of simulating CW-DCS and TD-DCS measurements from first principles. In our exploration of the parameter space, we could not find realistic measurement conditions under which TD-DCS outperformed CW-DCS. However, the parameter space for the optimization of the contrast to noise ratio of TD-DCS is large and complex, so our results do not imply that TD-DCS cannot indeed outperform CW-DCS under different conditions. We made our code available publicly for others in the field to find use cases favorable to TD-DCS. TD-DCS also provides a promising way to measure deep brain tissue dynamics using a short source-detector separation, which will benefit the development of technologies including high density DCS systems and image reconstruction using a limited number of source-detector pairs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.