Evidence map›Paper›PMID 35198716›Full record

ArticlePractical laboratory medicine2022

Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system.

Lutz Schwettmann, Astrid Lied, Ragnar Eriksen

Open access · goldAbstract read
In one paragraph

Article in Practical laboratory medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Lutz SchwettmannDep. of Medical Biochemistry, Clinical Diagnostic Center, Aalesund Hospital, Aalesund, Norway.
Astrid LiedDep. of Medical Biochemistry, Clinical Diagnostic Center, Aalesund Hospital, Aalesund, Norway.
Ragnar EriksenDep. of Gastroenterology, Medical Clinic, Aalesund Hospital, Aalesund, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFaecal immunochemical tests (FIT) for the detection of haemoglobin are widely used in the diagnostic pathway of colorectal cancer (CRC) in patients presenting with lower abdominal symptoms. Several quantitative immunochemical tests are available, however only a few tests are available on high throughput automated analyzers. Here we report the analytical and clinical evaluation of the Sentinel-FOB Gold assay on the Roche Cobas 8000 automated system.

designand Methods: The assessment of the analytical performance of the assay on the Roche Cobas analyzer comprised determination of imprecision, accuracy, limit of detection, linearity, carryover and prozone effect. In the clinical evaluation part of the study 163 patients presenting for coloscopy with lower abdominal symptoms were included in the study. Diagnostic accuracy and optimal cutoff of the FIT-assay were determined by comparing faecal haemoglobin (f-Hb) concentrations with coloscopy findings as reference.

resultsWe confirmed good analytical performance of the assay on the Roche Cobas system. Patients with CRC had significant higher f-Hb concentrations than patients with non-advanced adenomas and patients with normal findings by coloscopy. When applying a cutoff of 10 μg/g the sensitivity and specificity were 96.2% and 51.8%, respectively for CRC and 84.6% and 57.7% for CRC and advanced adenoma.

conclusionThe Sentinel-FOB Gold assay is appropriate for application on the automated Roche Cobas 8000 analyzer. The assay shows good analytical performance on the system. With regard to early detection of significant colorectal diseases a cutoff of 10 μg/g seems to be optimal.

Indexed as

Colorectal cancerEvaluationFaecal haemoglobinFaecal immunochemical test