Evidence map›Paper›PMID 35196989›Full record

ArticleBMC cardiovascular disorders2022

Coronary artery perforation after bioresorbable scaffold implantation treated with a new generation covered stent-OCT insights.

D Chen, R Gadeley, A Wang, N Jepson

Open access · goldAbstract readCase Reports
In one paragraph

Article in BMC cardiovascular disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

D ChenPrince of Wales Hospital, Barker Street, Randwick, NSW, 2031, Australia.
R GadeleyPrince of Wales Hospital, Barker Street, Randwick, NSW, 2031, Australia. rgadeley@me.com.
A WangUniversity of New South Wales, Sydney, NSW, 2052, Australia.
N JepsonPrince of Wales Hospital, Barker Street, Randwick, NSW, 2031, Australia.
Prince of Wales Hospital · AUAustralian Centre for Heart Health · AUUNSW Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCoronary artery perforation is a rare but potentially lethal complication of percutaneous coronary intervention (PCI) with an associated mortality of 7-17%. We report the case of coronary artery perforation complicating Absorb bioresorbable vascular scaffold (BVS) implantation and the associated technical challenges with managing this life-threatening complication. CASE REPORT: A 46-year-old male was referred to our institution and underwent PCI with an Absorb bioabsorbable vascular scaffold (BVS) to a proximal LAD long segment bifurcation lesion. Following pre-dilation and deployment of the 3.5 × 28 mm Absorb BVS, high pressure post-dilation of the distal scaffold was complicated by a large, Ellis type III coronary perforation with no flow to the distal LAD beyond the rupture, and associated with a large pericardial effusion confirmed on bedside transthoracic echocardiogram (TTE). The insult was temporised with prolonged balloon inflation within the Absorb BVS immediately proximal to the site of perforation, permitting urgent insertion of a pericardial drain. After deflation of the balloon, a 3.0 × 21 mm BeGraft covered stent was deployed across the perforation, restoring normal LAD flow and abolishing the perforation. Cardio-pulmonary resuscitation was not required and the patient remained conscious throughout the procedure. TTE demonstrated normal left ventricular function and the patient was discharged 3 days later. Repeat angiography at 3 months showed patent stents with TIMI III flow, and optical coherence tomography (OCT) showed good expansion and apposition of the proximal Absorb BVS and BeGraft. The patient has remained well 4 years after PCI with no major cardiovascular events.

conclusionThe utility of bioresorbable scaffold technology remains controversial although meticulous implantation techniques are associated with improved clinical outcomes. Adoption of the Pre-dilatation, Sizing and Post-dilatation ('PSP') method of BVS implantation with routine aggressive vessel preparation and scaffold optimization however may contribute to a higher risk of vessel perforation. The case emphasises the importance of accurate sizing of the vessel with intracoronary imaging and demonstrates the value of newer generation covered stents with single-layer design and slimmer crossing profile producing improved deliverability and procedural success.

Indexed as

Coronary Artery DiseaseDrug-Eluting StentsHeart InjuriesPercutaneous Coronary InterventionVascular System InjuriesAbsorbable ImplantsCoronary AngiographyEverolimusHumansMaleMiddle AgedProsthesis DesignStentsTomography, Optical CoherenceTreatment OutcomeEverolimusArteryBioresorbableCase reportCoherenceCoronaryOpticalPerforationStentTomography

Identifiers

PMID35196989
PMCPMC8864843
OpenAlexW4212807590

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked