ArticleActa biomaterialia2022
A high-accuracy and high-efficiency digital volume correlation method to characterize in-vivo optic nerve head biomechanics from optical coherence tomography.
Article in Acta biomaterialia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Advances in glaucoma biomechanics from 2000 to 2024: a bibliometric study and visualization analysis.Frontiers in neuroscience · 2025Pooled it
- Digital Volume Correlation Challenge 2.0: A Comprehensive Dataset for Digital Volume Correlation Benchmarking.Research square · 2026Article
- 3D Printed Patient-Specific Resorbable Bone Scaffolds for Alveolar Bone Regeneration.Tissue engineering and regenerative medicine · 2026Review
- Deep learning method for semi-automated segmentation of optic nerve head tissues in optical coherence tomography images.Experimental eye research · 2025Article
- Article
- Biomechanical Strain Responses in the Sclera, Choroid, and Retina in Glaucoma Patients After Intraocular Pressure Lowering.Journal of biomechanical engineering · 2025Article
- Proposing a Methodology for Axon-Centric Analysis of IOP-Induced Mechanical Insult.Investigative ophthalmology & visual science · 2024Article
- Impact of elevated IOP on lamina cribrosa oxygenation; A combined experimental-computational study on monkeys.bioRxiv : the preprint server for biology · 2024Article
- The Robust Lamina Cribrosa Vasculature: Perfusion and Oxygenation Under Elevated Intraocular Pressure.Investigative ophthalmology & visual science · 2024Article
- Denoising OCT videos based on temporal redundancy.Scientific reports · 2024Article
- Optical Coherence Tomography Angiography Demonstrates Strain and Volume Effects on Optic Disk and Peripapillary Vasculature Caused by Horizontal Duction.Current eye research · 2023Article
- Reverse translation of artificial intelligence in glaucoma: Connecting basic science with clinical applications.Frontiers in ophthalmology · 2023Article
- Comparing Acute IOP-Induced Lamina Cribrosa Deformations Premortem and Postmortem.Translational vision science & technology · 2022Article
- Impact of Elevated Intraocular Pressure on Lamina Cribrosa Oxygenation: A Combined Experimental-Computational Study on Monkeys.Ophthalmology scienceArticle
- Research progress of in vivo measurement methods of myopia sclera biomechanics.Advances in ophthalmology practice and researchReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
In-vivo optic nerve head (ONH) biomechanics characterization is emerging as a promising way to study eye physiology and pathology. We propose a high-accuracy and high-efficiency digital volume correlation (DVC) method to characterize the in-vivo ONH deformation from optical coherence tomography (OCT) volumes. Using a combination of synthetic tests and analysis of OCTs from monkey ONHs subjected to acutely elevated intraocular pressure, we demonstrate that our proposed methodology overcame several challenges for conventional DVC methods: First, a pre-registration technique was used to remove large ONH rigid body motion in OCT volumes which could lead to analysis failure; second, a modified 3D inverse-compositional Gaussian Newton method was used to ensure sub-voxel accuracy of displacement calculations despite high noise and low image contrast of some OCT volumes; third, a tricubic B-spline interpolation method was applied to improve computational efficiency; fourth, a confidence parameter was introduced to guide the searching path in the displacement calculation; fifth, a confidence-weighted strain calculation method was applied to further improve the accuracy. The proposed DVC method had displacement errors smaller than 0.037 and 0.028 voxels with Gaussian and speckle noises, respectively. The strain errors in the three directions were less than 0.0045 and 0.0018 with Gaussian and speckle noises, respectively. Compared with the conventional DVC method, the proposed method reduced the errors of displacement and strain calculations by up to 70% under large body motions, with 75% lower computation time, while saving about 30% memory. Our study demonstrates the potential of the proposed technique to investigate ONH biomechanics. STATEMENT OF SIGNIFICANCE: The biomechanics of the optic nerve head (ONH) in the posterior pole of the globe play a central role in eye physiology and pathology. The application of digital volume correlation (DVC) to the analysis of optical coherence tomography (OCT) images of the ONH has emerged as a promising way to quantify ONH biomechanics. Conventional DVC methods, however, face several important challenges when analyzing OCT images of the ONH. We introduce a high-accuracy and high-efficiency DVC method to characterize in vivo ONH deformations from OCT volumes. We demonstrate the new method using synthetic tests and actual OCT data from monkey ONHs. The new method also has the potential to be used to study other tissues, as OCT applications continue to expand.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.