Evidence map›Paper›PMID 35196371›Full record

ArticlePhysical therapy2022

Exploring Inertial-Based Wearable Technologies for Objective Monitoring in Sports-Related Concussion: A Single-Participant Report.

Dylan Powell, Samuel Stuart, Alan Godfrey

Abstract read
In one paragraph

Article in Physical therapy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Dylan PowellDepartment of Computer and Information Sciences, Northumbria University, Newcastle-upon-Tyne, United Kingdom.
Samuel StuartDepartment of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle-upon-Tyne, United Kingdom.
Alan GodfreyDepartment of Computer and Information Sciences, Northumbria University, Newcastle-upon-Tyne, United Kingdom.ORCID 0000-0003-4049-9291

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveChallenges remain in sports-related concussion (SRC) assessment to better inform return to play. Reliance on self-reported symptoms within the Sports Concussion Assessment Tool means that there are limited data on the effectiveness of novel methods to assess a player's readiness to return to play. Digital methods such as wearable technologies may augment traditional SRC assessment and improve objectivity in making decisions regarding return to play.

methodsThe participant was a male university athlete who had a recent history of SRC. The single-participant design consisted of baseline laboratory testing immediately after SRC, free-living monitoring, and follow-up supervised testing after 2 months. The primary outcome measures were from traditional assessment (eg, Sports Concussion Assessment Tool and 2-minute instrumented walk/gait test; secondary outcome measures were from remote (free-living) assessment with a single wearable inertial measurement unit (eg, for gait and sleep).

resultsThe university athlete (age = 20 years, height = 175 cm, weight = 77 kg [176.37 lb]) recovered and returned to play 20 days after SRC. Primary measures returned to baseline levels after 12 days. However, supervised (laboratory-based) wearable device assessment showed that gait impairments (increased step time) remained even after the athlete was cleared for return to play (2 months). Similarly, a 24-hour remote gait assessment showed changes in step time, step time variability, and step time asymmetry immediately after SRC and at return to play (1 month after SRC). Remote sleep analysis showed differences in sleep quality and disturbance (increased movement between immediately after SRC and once the athlete had returned to play [1 month after SRC]).

conclusionThe concern about missed or delayed SRC diagnosis is growing, but methods to objectively monitor return to play after concussion are still lacking. This report showed that wearable device assessment offers additional objective data for use in monitoring players who have SRC. This work could better inform SRC assessment and return-to-play protocols. IMPACT: Digital technologies such as wearable technologies can yield additional data that traditional self-report approaches cannot. Combining data from nondigital (traditional) and digital (wearable) methods may augment SRC assessment for improved return-to-play decisions. LAY SUMMARY: Inertia-based wearable technologies (eg, accelerometers) may be useful to help augment traditional, self-report approaches to sports-related concussion assessment and management by better informing return-to-play protocols.

Indexed as

Athletic InjuriesBrain ConcussionSportsWearable Electronic DevicesAdultGaitHumansMaleYoung AdultBrain ConcussionReturn to PlayRugbySports MedicineWearable Technologies

Identifiers

PMID35196371
PMCPMC9155164

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.