Evidence map›Paper›PMID 35195884›Full record

ArticleIndian journal of gastroenterology : official journal of the Indian Society of Gastroenterology2022

Endocuff-assisted push enteroscopy increases the detection of proximal small-bowel gastrointestinal angiodysplasias.

Christian S Jackson, Chandrasekhar Kesavan, Anjali Das, Erick Imbertson, Richard M Strong

Abstract read
PubMed Publisher
In one paragraph

Article in Indian journal of gastroenterology : official journal of the Indian Society of Gastroenterology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Christian S JacksonDepartment of Gastroenterology, VA Loma Linda Veterans Healthcare System (VALLHCS), 11201 Benton Street, Loma Linda, CA, 92357, USA.
Chandrasekhar KesavanDepartment of Gastroenterology, VA Loma Linda Veterans Healthcare System (VALLHCS), 11201 Benton Street, Loma Linda, CA, 92357, USA.
Anjali DasDepartment of Gastroenterology, VA Loma Linda Veterans Healthcare System (VALLHCS), 11201 Benton Street, Loma Linda, CA, 92357, USA.
Erick ImbertsonDepartment of Gastroenterology, VA Loma Linda Veterans Healthcare System (VALLHCS), 11201 Benton Street, Loma Linda, CA, 92357, USA.
Richard M StrongDepartment of Gastroenterology, VA Loma Linda Veterans Healthcare System (VALLHCS), 11201 Benton Street, Loma Linda, CA, 92357, USA. Richard.Strong3@va.gov.
VA Loma Linda Healthcare System · USLoma Linda University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gastrointestinal angiodysplasias (GIADs) are the most common causes for suspected small bowel bleeding. Fifty percent of GIADs do not need treatment due to bleeding cessation, while 45% have high re-bleeding rates, that significantly impact patient outcome and health resource utilization. We suspected that this high re-bleeding rate occurs because not all lesions are detected with present standard of care. This study evaluates whether device-assisted enteroscopy (DAE) utilizing the Endocuff (EC) device could improve GIAD detection. A retrospective chart review of a prospective data collection was performed from January 2006 to December 2018 at VA Loma Linda Healthcare System (VALLHCS) on both inpatients and outpatients referred for active and chronic suspected small bowel bleeding. The patients were initially monitored for bleeding lesions via video capsule endoscopy (VCE) after negative upper and lower endoscopy. GIADs observed between 0% to 40% small bowel transit time (SBTT) were referred for push enteroscopy (PE) with and without (±) the EC device. Twenty-five consecutive patients underwent PE ± EC. No patient had VCE done after PE ± EC. Using PE-EC, GIADs were detected in 9 of 25 (36%) of patients. Importantly, PE+EC detected GIADs in 23 of 25 (92%) patients. The sum of GIADs detected without EC was 26 ± 0.06 vs. 112 ± 0.2 using EC. The average detection rate for PE without EC was significantly lower (1.04 ± 0.06, mean ± SE) as compared to PE with EC (4.48 ± 0.23, mean ± SE, p<0.0005). Additionally, a positive correlation (r=0.51) between capsule enteroscopy (CE) location of GIADs and SBTT was found. The EC device increases the detection of GIADs in the proximal small bowel. We also reconfirm that the location of bleeding GIADs are within the reach of the push enteroscope (PE). Finally, PE + EC may also reduce GIAD miss rates, which may play a role in the reduction of re-bleeding episodes.

Indexed as

AngiodysplasiaCapsule EndoscopyVascular DiseasesEndoscopy, GastrointestinalGastrointestinal HemorrhageHumansIntestine, SmallRetrospective StudiesChronic gastrointestinal bleedingDeep enteroscopyDevice assisted enteroscopyEndocuffGastrointestinal angiodysplasiasGastrointestinal bleedingIron deficiency anemiaLanreotidePush enteroscopySmall bowel bleedingVideo capsule enteroscopy

Identifiers

PMID35195884
OpenAlexW4213151200

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.