Evidence map›Paper›PMID 35195730›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

Allograft contamination during suture preparation for anterior cruciate ligament reconstruction: an ex vivo study.

Chenliang Wu, Xiuyuan Zhang, Yi Qiao, Jiebo Chen, Wei Su, Junjie Xu, Zipeng Ye, Jia Jiang, Caiqi Xu, Guoming Xie and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Chenliang Wu *Department of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.ORCID http://orcid.org/0000-0001-6002-5232
Xiuyuan Zhang *Department of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Yi Qiao *Department of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Jiebo ChenDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Wei SuDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Junjie XuDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Zipeng YeDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Jia JiangDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Caiqi XuDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China.
Guoming XieDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China. xieguoming2006@163.com.
Jinzhong ZhaoDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China. jzzhao@sjtu.edu.cn.ORCID http://orcid.org/0000-0003-2265-1878
Song ZhaoDepartment of Sports Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, 200233, China. drzhaosong1980@163.com.
Shanghai Jiao Tong University · CN

Funding

Basic Research Program of Shanghai Sixth People's Hospital ynms202105National Key Research and Development Program of China 2018YFC1106200National Key Research and Development Program of China 2018YFC1106202Shanghai Pujiang Program 2020PJD041
6 · The paper itself

Abstract

purposeEffects of suture preparation on graft contamination remain unknown in anterior cruciate ligament reconstruction (ACLR). This study aimed to evaluate the incidence of allograft contamination at different time points of graft preparation and investigate differences in contamination between different sites of the allografts.

methodsFourteen hamstring tendon (HT), 9 quadriceps tendon (QT), and 9 bone-patellar tendon-bone (BTB) allografts were harvested, sterilised, and stored following routine procedures. Graft suture preparation was performed with baseball stitching for soft tissue and bone drilling for bone plug. The time was recorded simultaneously. The graft was kept moist in a standard operating room environment for 30 min after the initiation of preparation. The specimens were obtained from the middle and both ends of each graft for culture at three different time points: pre-suturing, post-suturing, and 30 min after the initiation of preparation. A total of 192 specimens were transferred to the microbiology laboratory for culture, identification, and semi-quantitative assessment. Culture results were classified as negative, poor, and abundant based on the extent of growth. Contamination level was recorded as low or high corresponding to culture results of poor or abundant.

resultsThe duration of suture preparation was 348, 301, and 246 s for HT, QT, and BTB (P = 0.090). The specimens had a positive culture rate of 41/192 (21.4%), of which 21 were from the ends and 20 from the middle. More positive samples with abundant bacterial growth were detected from the ends than from the middles post-suturing (7/8 vs. 1/7, P = 0.010) and at 30 min (6/11 vs. 0/11, P = 0.012). The total graft contamination rate was significantly higher at 30 min (19/32, 59.4%) than pre-suturing (4/32, 15.6%) and post-suturing (9/32, 28.1%) (P < 0.001). The contamination rate with abundant bacterial growth was higher post-suturing (7/32, 21.9%) than pre-suturing (0%). No statistically significant differences were found among the three types of allografts.

conclusionThe contamination rate increases significantly at 30 min compared with pre-suturing and post-suturing. Suture preparation may have introduced the high-level contamination, to which the ends of the graft were more prone than the middle. Therefore, routine prophylactic decontamination after suture preparation should be considered, especially for the ends of the grafts.

Indexed as

Anterior Cruciate Ligament InjuriesAnterior Cruciate Ligament ReconstructionHamstring TendonsAllograftsHumansSuturesTransplantation, AutologousAllograftAnterior cruciate ligament reconstructionContaminationSuture preparation

Identifiers

PMID35195730
OpenAlexW4213443205

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.