ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2022
Smart Contact Lens with Dual-Sensing Platform for Monitoring Intraocular Pressure and Matrix Metalloproteinase-9.
Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed, 90 citations in OpenAlex.
- Investigation Into the Collection and Isolation Workflows of Extracellular Vesicles From Tears.Journal of extracellular biology · 2026Article
- Nanomaterial-enabled smart contact lenses: bridging sensing, therapy, and theranostics for next-generation ocular healthcare.Journal of nanobiotechnology · 2026Review
- MMP-9-responsive contact lens facilitating disease-adaptive and safer dexamethasone delivery for corneal neovascularization therapy.Asian journal of pharmaceutical sciences · 2026Article
- Lighting the Path to Precision Healthcare: Advances and Applications of Wearable Photonic Sensors.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Photonic Nanomaterials for Wearable Health Solutions.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Optical Contact Lenses Biosensors.ACS sensors · 2025Review
- Wearable biomolecular sensing nanotechnologies in chronic disease management.Nature nanotechnology · 2025Review
- A Granular Hydrogel-Enabled Wearable Electrochemical Biosensing Platform for Continuous Non-Invasive Sweat Lactate Detection.Small (Weinheim an der Bergstrasse, Germany) · 2025Article
- Kirigami-Inspired Breathable Smart Contact Lens for Wireless Monitoring of Corneal Hypoxia and Microenvironment.Advanced healthcare materials · 2025Article
- Closed-eye intraocular pressure and eye movement monitoring via a stretchable bimodal contact lens.Microsystems & nanoengineering · 2025Article
- Microfluidic contact lens: fabrication approaches and applications.Microsystems & nanoengineering · 2025Review
- Fish Fin-Derived Non-Invasive Flexible Bioinspired Contact Lens for Continuous Ophthalmic Drug Delivery.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Revolutionary Point-of-Care Wearable Diagnostics for Early Disease Detection and Biomarker Discovery through Intelligent Technologies.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- A Comprehensive Review of Stimuli-Responsive Smart Polymer Materials-Recent Advances and Future Perspectives.Materials (Basel, Switzerland) · 2024Review
- Colorimetric sensing for translational applications: from colorants to mechanisms.Chemical Society reviews · 2024Review
- Neuroprosthetic contact lens enabled sensorimotor system for point-of-care monitoring and feedback of intraocular pressure.Nature communications · 2024Article
- Wearable Sensors for Physiological Condition and Activity Monitoring.Small science · 2024Article
- Smart Contact Lenses in Ophthalmology: Innovations, Applications, and Future Prospects.Micromachines · 2024Review
- Smart molecules in ophthalmology: Hydrogels as responsive systems for ophthalmic applications.Smart molecules : open access · 2024Review
- Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma.Science advances · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 2 institutions in 1 country.
Funding
Abstract
Contact lenses have become a popular health-monitoring wearable device due to their direct contact with the eyes. By integrating biosensors into contact lenses, real-time and noninvasive diagnoses of various diseases can be realized. However, current contact lens sensors often require complex electronics, which may obstruct the user's vision or even damage the cornea. Moreover, most of the reported contact lens sensors can only detect one analyte. Therefore, an optical-based dual-functional smart contact lens sensor has been introduced to monitor intraocular pressure (IOP) and detect matrix metalloproteinase-9 (MMP-9), both of which are key biomarkers in many eye-related diseases such as glaucoma. Specifically, the elevated IOP is continuously monitored by applying an antiopal structure through color changes, without any complex electronics. Together with the peptide modified gold nanobowls (AuNBs) surface-enhanced Raman scattering (SERS) substrate, the quantitative analysis of MMP-9 at a low nanomolar range is achieved in real tear samples. The dual-sensing functions are thus demonstrated, providing a convenient, noninvasive, and potentially multifunctional sensing platform for monitoring health and diagnostic biomarkers in human tears.