Evidence map›Paper›PMID 35191035›Full record

ArticleMedical physics2022

Technical note: Controlling the attenuation of 3D-printed physical phantoms for computed tomography with a single material.

Huayu Tong, Hope Pegues, Ehsan Samei, Joseph Y Lo, Benjamin J Wiley

Abstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Huayu TongDepartment of Chemistry, Duke University, Durham, North Carolina, USA.
Hope PeguesMedical Physics Graduate Program, Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University School of Medicine, Durham, North Carolina, USA.
Ehsan SameiDepartment of Chemistry, Duke University, Durham, North Carolina, USA.
Joseph Y LoMedical Physics Graduate Program, Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University School of Medicine, Durham, North Carolina, USA.
Benjamin J WileyDepartment of Chemistry, Duke University, Durham, North Carolina, USA.

Funding

3D Printing of Anatomically Realistic Phantoms for Optimization of Imaging AlgorithmsR21EB025549 · NIBIB · DUKE UNIVERSITY · PI LO, JOSEPH Y, WILEY, BENJAMIN J. · 2018 to 2019
$420k
NIBIB NIH HHS R21 EB025549NIH/NIBIB R21EB025549
6 · The paper itself

Abstract

purposeThe purpose of this work was to characterize and improve the ability of fused filament fabrication to create anthropomorphic physical phantoms for CT research. Specifically, we sought to develop the ability to create multiple levels of X-ray attenuation with a single material.

methodsCT images of 3D printed cylinders with different infill angles and printing patterns were assessed by comparing their 2D noise power spectra to determine the conditions that produced minimal and uniform noise. A backfilling approach in which additional polymer was extruded into an existing 3D printed background layer was developed to create multiple levels of image contrast.

resultsA print with nine infill angles and a rectilinear infill pattern was found to have the best uniformity, but the printed objects were not as uniform as a commercial phantom. An HU dynamic range of 600 was achieved by changing the infill percentage from 40% to 100%. The backfilling technique enabled control of up to eight levels of contrast within one object across a range of 200 HU, similar to the range of soft tissue. A contrast detail phantom with six levels of contrast and an anthropomorphic liver phantom with four levels of contrast were printed with a single material.

conclusionThis work improves the uniformity and levels of contrast that can be achieved with fused filament fabrication, thereby enabling researchers to easily create more detailed physical phantoms, including realistic, anthropomorphic textures.

Indexed as

Printing, Three-DimensionalTomography, X-Ray ComputedAbdomenPhantoms, Imaging3D printingcomputed tomographyphysical phantom

Identifiers

PMID35191035
PMCPMC12157748

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.