Evidence map›Paper›PMID 35190223›Full record

ArticleZeitschrift fur medizinische Physik2023

Free-breathing half-radial dual-echo balanced steady-state free precession thoracic imaging with wobbling Archimedean spiral pole trajectories.

Oliver Bieri, Orso Pusterla, Grzegorz Bauman

Erratum issuedAbstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Feasibility and SNR Performance of HyperpolarizedMagnetic resonance in medicine · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Oliver BieriDivision of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
Orso PusterlaDivision of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; Department of Biomedical Engineering, University of Basel, Basel, Switzerland.
Grzegorz BaumanDivision of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland; Department of Biomedical Engineering, University of Basel, Basel, Switzerland. Electronic address: grzegorz.bauman@usb.ch.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo demonstrate free-breathing thoracic MRI with a minimal-TR balanced steady-state free precession (bSSFP) technique using wobbling Archimedean spiral pole (WASP) trajectories.

methodsPhantom and free-breathing in vivo chest imaging in healthy volunteers was performed at 1.5T with a half-radial, dual-echo, bSSFP sequence, termed bSTAR. For maximum sampling efficiency, a single analog-to-digital converter window along the full bipolar readout was used. To ensure a homogeneous coverage of the k-space over multiple breathing cycles, radial k-space sampling followed short-duration Archimedean spiral interleaves that were randomly titled by a small polar angle and rotated by a golden angle about the polar axis; depticting a wobbling Archimedean spiral pole (WASP) trajectory. In phantom and in vivo experiments, WASP trajectories were compared to spiral phyllotaxis sampling in terms of eddy currents and were used to generate in vivo thorax images at different respiratory phases.

resultsWASP trajectories provided artifact-free bSTAR imaging in both phantom and in vivo and respiratory self-gated reconstruction was successfully performed in all subjects. The amount of the acquired data allowed the reconstruction of 10 volumes at different respiratory levels with isotropic resolution of 1.77mm from a scan of 5.5minutes (using a TR of 1.32ms), and one high-resolution 1.16mm end-expiratory volume from a scan of 4.7minutes (using a TR of 1.42ms). The very short TR of bSTAR mitigated off-resonance artifacts despite the large field-of-view.

conclusionWe have demonstrated the feasibility of high-resolution free-breathing thoracic imaging with bSTAR using the wobbling Archimedean spiral pole in healthy subjects at 1.5T.

Indexed as

Magnetic Resonance ImagingRespirationArtifactsHumansPhantoms, ImagingThoraxBalanced steady-state free precessionFree-breathingLung imagingNon-Cartesian trajectoryRadial MRITrueFISP

Identifiers

PMID35190223
PMCPMC10311259

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.