Shift detection discrepancy between ExacTrac Dynamic system and cone-beam computed tomography.
Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Correction of image-guided radiotherapy and intrafraction motion using ExacTrac dynamic for head and neck cancer patients.Technical innovations & patient support in radiation oncology · 2026Article
- Comparison of surface-guided radiotherapy-based deep inspiration breath hold and continuous positive airway pressure techniques in left-sided breast cancer: dosimetric and workflow analysis.Physical and engineering sciences in medicine · 2026Article
- To shift or not to shift: identifying and correcting patient motion after couch rotations in non-coplanar intracranial radiosurgery with stereoscopic X-ray imaging.Journal of applied clinical medical physics · 2026Article
- Commissioning of a combined stereoscopic x-ray and surface guided radiotherapy system for performing breath hold gated lung radiotherapy.Journal of applied clinical medical physics · 2025Article
- Impact of intrafraction fiducial tracking on planning target margins during prostate stereotactic body radiotherapy using Brainlab ExacTrac Dynamic with robotic couch correction.Journal of applied clinical medical physics · 2025Article
- Integrating surface-guided radiation therapy and continuous positive airway pressure for breast cancer: Improving reproducibility and efficacy.Journal of applied clinical medical physics · 2025Article
- Stereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Article
- Clinical Experience of Intrafractional Motion Monitoring of Patients Under Head and Neck Radiation Therapy Using ExacTrac Dynamic System.Advances in radiation oncology · 2024Article
- Stereotactic Radiosurgery of Multiple Brain Metastases: A Review of Treatment Techniques.Cancers · 2023Review
- Initial end-to-end testing of the ExacTrac dynamic deep inspiration breath hold workflow using a breath hold breast phantom.Physical and engineering sciences in medicine · 2023Article
- ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning.Journal of applied clinical medical physics · 2022Article
- Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate detection of patient shift is essential during radiation therapy such that optimal dose is delivered to the tumor while minimizing radiation to surrounding normal tissues. The shift detectability of a newly developed optical surface and thermal tracking system, which was known as ExacTrac Dynamic (EXTD), was evaluated by comparing its performance with the image guidance under cone-beam computed tomography (CBCT). Anthropomorphic cranial and pelvis phantoms with internal bone-like structures and external heat pad were utilized to study the shift detection discrepancy between EXTD system and CBCT. Random displacements within the range of ± 2 cm for translations and ± 2 degrees for rotations were intentionally applied to the phantom. Positional shifts detected by optical surface and thermal tracking (EXTD_Thml), stereoscopic X-ray (EXTD_Xray), and CBCT were compared in 6 degrees of freedom. The translational difference between EXTD_Thml and CBCT was 0.57 ± 0.41 mm and 0.66 ± 0.40 mm for cranial and pelvis phantom, respectively, while it was 0.60 ± 0.43 mm and 0.76 ± 0.49 mm between EXTD_Xray and CBCT, respectively. For rotational movement, the difference between EXTD_Thml and CBCT was 0.19 ± 0.16° and 0.19 ± 0.22° for cranial and pelvis phantom, respectively, while it was 0.13 ± 0.18° and 0.65 ± 0.46° between EXTD_Xray and CBCT, respectively. This study demonstrated that the EXTD system with thermal mapping ability could offer comparable accuracy for shift detection with CBCT on both cranial and pelvis phantoms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.