Evidence map›Paper›PMID 35187813›Full record

ArticleClinical and experimental dental research2022

Comparison of internal fit of metal-ceramic crowns in CAD/CAM and lost-wax techniques in all fabrication stages through replica weighting, triple scanning, and scanning electron microscope.

Sina Mohammadi Sadr, Elham Ahmadi, Masoumeh Hasani Tabatabaei, Saba Mohammadi, Faezeh Atri

Open access · goldAbstract read
In one paragraph

Article in Clinical and experimental dental research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sina Mohammadi SadrDepartment of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0003-1073-350X
Elham AhmadiDepartment of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0002-3428-1045
Masoumeh Hasani TabatabaeiDepartment of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0001-8318-0163
Saba MohammadiSchool of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0002-6957-1392
Faezeh AtriDental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0002-4334-6154
Tehran University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesRestoration fit is one of the prerequisites of clinical durability. It is controversial as to whether computer-assisted design/computer-aided milling (CAD/CAM) or lost-wax fabrication methods result in more fit metal-ceramic crowns. This in-vitro study was conducted to examine the internal fit of porcelain fused to metal crowns fabricated using CAD/CAM and lost-wax techniques during fabrication stages (framework, porcelain, cementation) through digital triple scanning, replica weighting, and observation with electron microscopy. MATERIAL AND

methodsTwenty uniform resin dies of prepared first maxillary molars were randomly divided into two groups according to the fabrication technique: lost wax and CAD/CAM. The internal fit was measured in all steps of completing the crowns (framework, porcelain, and cementation) using different methods, including triple scanning, replica weighting, and scanning electron microscopy. The data were statistically analyzed using t test, Pearson, and repeated measures analysis of variance (α = .05).

resultsTriple scanning revealed no difference in the internal fit of CAD/CAM and lost-wax groups in all the fabrication steps (p > .05). The replica weighting method showed no difference between groups in the framework step (p > .05), while the internal fit was significantly better in the CAD/CAM group after porcelain application (p < .05). After cementation, electron microscopy measurements showed no difference between CAD/CAM and lost wax groups (p > .05). The Pearson correlation test showed no significant correlation between electron microscopy, replica weighing, and triple scanning methods (p > .05).

conclusionAccording to scanning electron microscopy as the superior evaluation method, the internal fit of cobalt-chrome PFM crown of both CAD/CAM and lost wax groups was within the acceptable clinical range and there was no significant difference between them. Triple scanning revealed no difference in the internal fit of framework and porcelain steps but a better fit after cementation. According to replica weighting, the internal fit in the porcelain step was higher than the framework.

Indexed as

Dental Marginal AdaptationDental PorcelainComputer-Aided DesignCrownsDental Prosthesis DesignMicroscopy, Electron, ScanningDental PorcelainCAD/CAMinternal fitlost waxmetal ceramic alloys

Identifiers

PMID35187813
PMCPMC9209789
OpenAlexW4212990810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.