Evidence map›Paper›PMID 35182254›Full record

ArticleEmergency radiology2022

Association between the corrosion of ingested lithium button battery in the esophagus and its complications in pediatric patients.

Takahiro Hosokawa, Yutaka Tanami, Yumiko Sato, Masashi Yoshida, Ryo Ebana, Tomoko Hara, Ryusuke Nambu, Itaru Iwama, Eiji Oguma

Abstract read
PubMed Publisher
In one paragraph

Article in Emergency radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Takahiro HosokawaDepartment of Radiology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan. snowglobe@infoseek.jp.ORCID http://orcid.org/0000-0001-9523-4077
Yutaka TanamiDepartment of Radiology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Yumiko SatoDepartment of Radiology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Masashi YoshidaDivision of Gastroenterology and Hepatology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Ryo EbanaDivision of Gastroenterology and Hepatology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Tomoko HaraDivision of Gastroenterology and Hepatology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Ryusuke NambuDivision of Gastroenterology and Hepatology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Itaru IwamaDivision of Gastroenterology and Hepatology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Eiji OgumaDepartment of Radiology, Saitama Children's Medical Center, 1-2 Shintoshin Chuo-ku Saitama, Saitama, 330-8777, Japan.
Saitama Children's Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe incidence of lithium button battery ingestion has been increasing recently, which results in severe complications. We aimed to demonstrate the association between the corrosion of lithium button batteries in the esophagus on radiographs and their complications.

methodsThe nine pediatric patients included in this study were classified into two groups based on the presence of severe complications. The presence and degree of corrosion on plain radiographs were evaluated. The degree of corrosion was classified into the following three grades; none: 0%; moderate: 1-50%; severe: 51-100%. Fisher's exact test was used for statistical analyses.

resultsOf the nine patients, five showed complications. The number of patients who had grade none, moderate, and severe degrees of corrosion was three, four, and two, respectively. The incidence of severe complications differed significantly between the incidence of lithium button batteries' contour (without vs. with severe complications [presence/absence of corrosion] = 1/3 vs. 5/0, respectively; P = 0.0476). In cases with "none" degree of corrosion, all three cases had no complication, and in cases with a "severe" degree of corrosion, all two cases had complications.

conclusionThe cases with the presence of corrosion of lithium button batteries had a higher tendency to have severe complications. Therefore, physicians should anticipate the presence of severe complications in pediatric patients with corrosion more than those without corrosion.

Indexed as

Foreign BodiesLithiumChildCorrosionElectric Power SuppliesEsophagusHumansLithiumChildrenForeign body ingestionLithium button batteryPediatricRadiograph

Identifiers

PMID35182254
OpenAlexW4213008698

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials