Evidence map›Paper›PMID 35179702›Full record

ArticleLa Radiologia medica2022

Fluid-dynamic control microcatheter used with glue: preliminary experience on its feasibility and safety.

Anna Maria Ierardi, Elvira Stellato, Giuseppe Pellegrino, Cristian Bonelli, Michaela Cellina, Matteo Renzulli, Pierpaolo Biondetti, Gianpaolo Carrafiello

Open access · bronzeAbstract read
In one paragraph

Article in La Radiologia medica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Immunotherapy Assessment: A New Paradigm for Radiologists.Diagnostics (Basel, Switzerland) · 2023
    Review
  13. Review
  14. Review
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Anna Maria IerardiRadiology Department, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20122, Milan, Italy. amierardi@yahoo.it.ORCID http://orcid.org/0000-0002-3033-9713
Elvira StellatoPostgraduation School in Radiodiagnostics, University of Milan, via Festa del Perdono, 20122, Milan, Italy.
Giuseppe PellegrinoPostgraduation School in Radiodiagnostics, University of Milan, via Festa del Perdono, 20122, Milan, Italy.
Cristian BonelliHealthcare Professional Department, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy.
Michaela CellinaRadiology Department, ASST Fatebenefratelli Sacco, piazza Principessa Clotilde 3, 20121, Milan, Italy.
Matteo RenzulliDepartment of Radiology, IRCCS Azienda Ospedaliero-Universitaria Di Bologna, Via Albertoni 15, Bologna, Italy.
Pierpaolo BiondettiRadiology Department, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20122, Milan, Italy.
Gianpaolo CarrafielloRadiology Department, Foundation IRCCS Cà Granda Ospedale Maggiore Policlinico, Via Francesco Sforza, 35, 20122, Milan, Italy.
Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico · ITUniversity of Milan · ITASST Fatebenefratelli Sacco · ITAzienda USL di Bologna · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate feasibility, safety, and success of peripheral embolization procedures carried out using anti-reflux microcatheter with N-butyl-cyanoacrylate (NBCA) as an embolic agent.

methodsWe retrospectively described 11 patients that suffered from active bleeding in different body districts, who underwent embolization procedure using SeQure microcatheter (Guerbet, France) with NBCA glue (Glubran II, GEM Italy) as an embolic agent. The treatments required NBCA volumes ranged from 0.1 to 0.6 mL, with different dilutions with ethiodized oil (Lipiodol, Guerbet, France), depending on the entity of the bleeding. Technical success, clinical success, and complications were evaluated.

resultsThe procedures were successfully concluded in the totality of the patients, achieving full technical and clinical success. In one patient (9.1%), a small upstream of embolic material was encountered, without any consequence.

conclusionThis preliminary experience shows that the use of SeQure is feasible and safe with NBCA.

Indexed as

Embolization, TherapeuticEnbucrilateEthiodized OilFeasibility StudiesHumansRetrospective StudiesTreatment OutcomeEnbucrilateEthiodized OilAnti-reflux microcatheterBleedingEmbolic agentsEmbolizationNBCA

Identifiers

PMID35179702
PMCPMC8855747
OpenAlexW4212913064

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.