ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2022
Establishing a through-puncture model for assessing post-injection leakage in the intervertebral disc.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Exploring Injectable Scaffolded Spheroids for Nucleus Pulposus Therapy in Degenerated Intervertebral Discs.ACS applied materials & interfaces · 2026Article
- Establishment of rabbit models of lumbar disc degeneration using three methods monitored via X-ray: a comparative study.Journal of orthopaedic surgery and research · 2025Article
- Complex In Vivo Motion of the Bovine Tail Provides Unique Insights Into Intervertebral Disc Adaptation.JOR spine · 2025Article
- Papain Injection Creates a Nucleotomy-like Cavity for Testing Gels in Intervertebral Discs.Gels (Basel, Switzerland) · 2024Article
- PGC1α-Inducing Senomorphic Nanotherapeutics Functionalized with NKG2D-Overexpressing Cell Membranes for Intervertebral Disc Degeneration.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- Intervertebral disc degeneration-Current therapeutic options and challenges.Frontiers in public health · 2023Review
- Intradiscal injection of human recombinant BMP-4 does not reverse intervertebral disc degeneration induced by nuclectomy in sheep.Journal of orthopaedic translation · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeNeedle injection through the outer annulus fibrosus of the intervertebral disc (IVD) is the most practical approach for delivery of therapeutic agents, which have been shown to potentially leak following needle retraction. The goal of this work was to establish a protocol for quantifying post-injection leakage and test its sensitivity to factors believed to affect needle track geometry.
methodsA through-puncture defect procedure, followed by controlled injection, was performed on bovine caudal IVDs. Sensitivity to needle size was tested by injection of saline into unconstrained discs with either a 30G, 26G, or 21G hypodermic needle. Sensitivity to axial load was tested by repeated injection via a 26G needle with either no constraint, fixed height, or 10% axial compressive strain. Sensitivity to flexion was tested by applying combined 0.2 MPa compression and 15° of flexion following injection of 5% of disc volume.
resultsNeedle diameter significantly affected maximum volume prior to leakage, ranging from 34.6 ± 31.9 µL when using 21G to 115.6 ± 23.6 µL when using 30G. While all unloaded discs leaked, axial compression decreased the incidence of leakage events by 50-100% depending on load history. Forward flexion resulted in a 22% incidence of leakage.
conclusionFluid injected into IVDs is at significant risk of leakage following needle retraction. This risk depends on factors which alter the geometry of the needle track, including needle size, pinching due to axial compression, and stretching as a result of forward flexion.