Evidence map›Paper›PMID 35179320›Full record

ArticleESC heart failure2022

Clinical study on the treatment of chronic heart failure with a novel D-shant atrium shunt device.

Xiaoke Shang, Mei Liu, Yucheng Zhong, Xueli Wang, Song Chen, Xiaojuan Fu, Ming Sun, Mingxing Xie, Yuhe Ke, Ying Guan and 2 more

Open access · goldAbstract read
In one paragraph

Article in ESC heart failure, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Left Atrial Hemodynamics and Clinical Utility in Heart Failure.Reviews in cardiovascular medicine · 2024
    Review
  6. Interatrial Shunt Devices.Heart failure clinics · 2024
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 6 institutions in 1 country.

Xiaoke ShangCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Mei LiuCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Yucheng ZhongDepartment of Cardiovascular Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xueli WangCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Song ChenCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Xiaojuan FuCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Ming SunCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Mingxing XieDepartment of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Yuhe KeDepartment of Hospital Infection Office, Wuhan No. 1 Hospital, Wuhan, China.
Ying GuanDepartment of Hospital Infection Office, Wuhan No. 1 Hospital, Wuhan, China.
Changdong ZhangCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Nianguo DongCardiac Laboratory, Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Jianghan District, Wuhan, Hubei Province, 430022, China.
Huazhong University of Science and Technology · CNUnion Hospital · CNUnion Hospital · CNWuhan No.1 Hospital · CNWuhan No.9 Hospital · CNWuhan Union Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAtrial septal shunt devices might improve hospitalizations and also prognosis in heart failure with increased pulmonary pressures due to left heart diseases. In recent years, atrial shunt devices have been used for the treatment of chronic heart failure, but there remains a lack of clinical experience. This study aimed to analyse the therapeutic effect of a novel type of atrial shunt on chronic heart failure. METHODS AND

resultsFrom May 2020 to September 2020, six patients who were diagnosed with chronic heart failure and completed percutaneous D-shant atrium shunt device implantation in the Department of Cardiovascular Surgery, Union Hospital, were retrospectively included. The shunt location was evaluated by echocardiography and digital subtraction angiography. Heart function was evaluated by New York Heart Association functional class. Echocardiography was used to measure the diameter of the new chamber and ventricle, and to evaluate the degree of mitral and tricuspid regurgitation. Before operation and 6 months after operation, left atrial end-diastolic volume, right atrial end-diastolic volume, left ventricular end-diastolic volume, and right ventricular end-diastolic volume were measured by magnetic resonance imaging. Left ventricular ejection fractions and right ventricular ejection fractions were calculated. Haemodynamic indexes of right heart catheterization and clinical cardiac function indexes were collected and compared before and 6 months after shunt implantation. All six patients completed percutaneous shunt device implantation. Echocardiography and digital subtraction angiography showed that the shunt device was correctly positioned and unobstructed in all patients. Echocardiography revealed that the left ventricular diameter decreased significantly from 6.40 ± 0.57 mm to 5.03 ± 0.73 mm (P < 0.05). There was an obvious decrease in mitral regurgitation. Magnetic resonance imaging showed a reduction in the volume of the left ventricle (182.00 ± 27.02 mL vs. 125.75 ± 16.11 mL, P < 0.05). Cardiac catheter examination showed the mean left atrium pressure or pulmonary capillary wedge pressure decreased postoperatively (31.83 ± 11.55 vs. 18.00 ± 5.51 mmHg, P < 0.05). There was also obvious improvement in clinical indicators of cardiac function at 6 months after implantation.

conclusionsThis novel D-shant atrium shunt device revealed maintained good function, no dislodgement and no paradoxical emboli. After implantation, functional mitral regurgitation in all patients with heart failure with reduced ejection fraction improved.

Indexed as

Heart FailureMitral Valve InsufficiencyChronic DiseaseHeart AtriaHumansRetrospective StudiesAtrial shunt deviceEjection fractionHeart failure

Identifiers

PMID35179320
PMCPMC9065846
OpenAlexW4212996683

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.