ArticleJournal of healthcare engineering2022
A Torn ACL Mapping in Knee MRI Images Using Deep Convolution Neural Network with Inception-v3.
Article in Journal of healthcare engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 3 syntheses or guidelines pooled it, 29 citations in OpenAlex.
- Artificial intelligence demonstrates comparable diagnostic accuracy to radiologists for anterior cruciate ligament tears on MRI: A systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Pooled it
- AI demonstrates comparable diagnostic performance to radiologists in MRI detection of anterior cruciate ligament tears: a systematic review and meta-analysis.European radiology · 2026Pooled it
- MRI deep learning models for assisted diagnosis of knee pathologies: a systematic review.European radiology · 2025Pooled it
- Artificial Intelligence Applications in Implant Positioning, Dislocation Risk Prediction, and Surgical Indications in Orthopaedic Surgery.Bioengineering (Basel, Switzerland) · 2026Review
- Artificial Intelligence in Anterior Cruciate Ligament Tear Diagnosis: A Bibliometric Analysis of the 50 Most Cited Studies.The Indian journal of radiology & imaging · 2026Review
- The revolutionary impact of artificial intelligence in orthopedics: comprehensive review of current benefits and challenges.Journal of robotic surgery · 2025Review
- Improving inceptionV4 model based on fractional-order snow leopard optimization algorithm for diagnosing of ACL tears.Scientific reports · 2024Article
- The Role of Artificial Intelligence in Anterior Cruciate Ligament Injuries: Current Concepts and Future Perspectives.Healthcare (Basel, Switzerland) · 2024Review
- A Novel Deep Learning Model to Distinguish Malignant Versus Benign Solid Lung Nodules.Medical science monitor : international medical journal of experimental and clinical research · 2022Article
- Hyperspectral Image Classification Model Using Squeeze and Excitation Network with Deep Learning.Computational intelligence and neuroscience · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 6 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The anterior cruciate ligaments (ACL) are the fundamental structures in preserving the common biomechanics of the knees and most frequently damaged knee ligaments. An ACL injury is a tear or sprain of the ACL, one of the fundamental ligaments in the knee. ACL damage most generally happens during sports, for example, soccer, ball, football, and downhill skiing, which include sudden stops or changes in direction, jumping, and landings. Magnetic resonance imaging (MRI) has a major role in the field of diagnosis these days. Specifically, it is effective for diagnosing the cruciate ligaments and any related meniscal tears. The primary objective of this research is to detect the ACL tear from MRI knee images, which can be useful to determine the knee abnormality. In this research, a Deep Convolution Neural Network (DCNN) based Inception-v3 deep transfer learning (DTL) model was proposed for classifying the ACL tear MRI images. Preprocessing, feature extraction, and classification are the main processes performed in this research. The dataset utilized in this work was collected from the MRNet database. A total of 1,370 knee MRI images are used for evaluation. 70% of data (959 images) are used for training and testing, and 30% of data (411 images) are used in this model for performance analysis. The proposed DCNN with the Inception-v3 DTL model is evaluated and compared with existing deep learning models like VGG16, VGG19, Xception, and Inception ResNet-v28. The performance metrics like accuracy, precision, recall, specificity, and F-measure are evaluated to estimate the performance analysis of the model. The model has obtained 99.04% training accuracy and 95.42% testing accuracy in performance analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.