Evidence map›Paper›PMID 35177663›Full record

ArticleScientific reports2022

Towards machine learning aided real-time range imaging in proton therapy.

Jorge Lerendegui-Marco, Javier Balibrea-Correa, Víctor Babiano-Suárez, Ion Ladarescu, César Domingo-Pardo

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Recent advances in applying machine learning to proton radiotherapy.Biomedical physics & engineering express · 2025
    Pooled it
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Jorge Lerendegui-MarcoInstituto de Física Corpuscular, CSIC-University of Valencia, Valencia, Spain. jorge.lerendegui@ific.uv.es.
Javier Balibrea-CorreaInstituto de Física Corpuscular, CSIC-University of Valencia, Valencia, Spain.
Víctor Babiano-SuárezInstituto de Física Corpuscular, CSIC-University of Valencia, Valencia, Spain.
Ion LadarescuInstituto de Física Corpuscular, CSIC-University of Valencia, Valencia, Spain.
César Domingo-PardoInstituto de Física Corpuscular, CSIC-University of Valencia, Valencia, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by [Formula: see text]-ray energies spanning up to 5-6 MeV, rather low [Formula: see text]-ray emission yields and very intense neutron induced [Formula: see text]-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high [Formula: see text]-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl[Formula: see text] crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr[Formula: see text]. Its high time-resolution (CRT [Formula: see text] 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl[Formula: see text] monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV [Formula: see text]-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10[Formula: see text] protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy [Formula: see text]-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.

Indexed as

Diagnostic ImagingImage Processing, Computer-AssistedMachine LearningProton TherapyPhantoms, Imaging

Identifiers

PMID35177663
PMCPMC8854574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.