Evidence map›Paper›PMID 35175183›Full record

ArticleBlood transfusion = Trasfusione del sangue2022

ABO antibody titres: a multisite comparative study of equivalency and reproducibility for automated solid-phase and haemagglutination titration, and manual dilution with gel column agglutination technology.

Dana Schneider, Mariangela Vicarioto, Serelina Coluzzi, Antonella Matteocci, Nicoletta Revelli, Barbara Foglieni, Patrizia Artusi, Donatella Londero, Anna Quaglietta, Giancarla Barrotta and 3 more

Open access · greenAbstract readEquivalence Trial
In one paragraph

Article in Blood transfusion = Trasfusione del sangue, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 3 institutions in 1 country.

Dana SchneiderImmucor Inc., Norcross, GA, United States of America.
Mariangela VicariotoDepartment of Transfusion Medicine, University Hospital of Padua, Padua, Italy.
Serelina ColuzziBlood Transfusion Service and Haematology, Umberto I Hospital, Rome, Italy.
Antonella MatteocciTransfusion Medicine Unit, San Camillo Forlanini Hospital, Rome, Italy.
Nicoletta RevelliDepartment of Transfusion Medicine and Haematology and Lombardy Regional Rare Blood Bank, IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Barbara FoglieniDepartment of Transfusion Medicine and Haematology ASST Lecco, Lecco, Italy.
Patrizia ArtusiDepartment of Transfusion Medicine, Azienda Ospedaliera Universitaria Policlinico, Modena, Italy.
Donatella LonderoDepartment of Transfusion Medicine, Azienda Sanitaria Universitaria Friuli Centrale, Udine, Italy.
Anna QuagliettaDepartment of Haematolgy and Oncology, Center of Transfusion Medicine, Pescara General Hospital, Pescara, Italy.
Giancarla BarrottaDepartment of Transfusion Medicine, Giovanni Paolo II Hospital, Ragusa, Italy.
Domenico VisceglieBlood Transfusion Service, Di Venere Hospital Bari, Italy.
Giuseppina PortararoDepartment of Transfusion Medicine, University Hospital, Parma, Italy.
Jonella GilsdorfImmucor Inc., Norcross, GA, United States of America.
Azienda USL di Pescara · ITCarlo Forlanini Hospital · ITUniversity of Padua · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundABO antibody titres are important in many clinical decisions; however, much variability is observed in titre results. For reliable and reproducible titre results, automated ABO titration methods have been developed. In this 10-site study, we evaluated the equivalency of the automated ABO titration assays on the Galileo NEO, a fully automated blood bank analyzer (Immucor, Inc.) to manual titration with gel Column Agglutination Technology (CAT), as well as the reproducibility of both methods. MATERIALS AND

methodsTen different locations participated in this study. The equivalency study included 70 random samples at each site. The reproducibility study tested the same blinded 30-sample panel at each study site. Anti-A and anti-B IgM and IgG antibody titres were tested with both the automated and manual methods; additionally, dithiothreitol (DTT) treatment was used to inactivate IgM antibodies in the manual CAT method.

resultsThe equivalency between CAT manual method and Galileo NEO automated titres at each site ranged from 38 to 88%; equivalency for each isotype was 66.2% for IgM, 60.6% for IgG, and 88.5% for DTT-treated IgG. The reproducibility study evaluated the titre variation of each sample obtained from the 10 sites. The average titre ranges (in doubling dilutions) for the automated and manual methods, respectively, were 2.15±1.0 and 4.03±1.8 for IgM, and 1.53±0.7 and 4.10±1.9 for IgG; for the manual DTT-treated IgG, the average titre range was 3.45±1.8 doubling dilutions. DISCUSSION: The results demonstrated that the Galileo NEO automated and manual CAT ABO titres are not equivalent. However, the study also demonstrated that titre reproducibility is enhanced with the Galileo NEO automated ABO titration assays relative to the manual CAT ABO titration method. Therefore, to improve management of patients receiving care across multiple institutions, our study supports the use of automated ABO titration.

Indexed as

ABO Blood-Group SystemHemagglutinationHumansImmunoglobulin GImmunoglobulin MReproducibility of ResultsTechnologyABO Blood-Group SystemImmunoglobulin GImmunoglobulin M

Identifiers

PMID35175183
PMCPMC9256507
OpenAlexW4212999054

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.