ArticleFrontiers in medicine2022

Removing Clinical Motion Artifacts During Ventilation Monitoring With Electrical Impedance Tomography: Introduction of Methodology and Validation With Simulation and Patient Data.

Lin Yang, Shuoyao Qu, Yanwei Zhang, Ge Zhang, Hang Wang, Bin Yang, Canhua Xu, Meng Dai, Xinsheng Cao

Abstract read
In one paragraph

Article in Frontiers in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lin YangDepartment of Aerospace Medicine, Fourth Military Medical University, Xi'an, China.
Shuoyao QuDepartment of Pulmonary and Critical Care Medicine, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
Yanwei ZhangDepartment of Medical Imaging, Bethune International Peace Hospital, Shijiazhuang, China.
Ge ZhangDepartment of Medical Imaging, Bethune International Peace Hospital, Shijiazhuang, China.
Hang WangDepartment of Aerospace Medicine, Fourth Military Medical University, Xi'an, China.
Bin YangDepartment of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.
Canhua XuDepartment of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.
Meng DaiDepartment of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.
Xinsheng CaoDepartment of Aerospace Medicine, Fourth Military Medical University, Xi'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveElectrical impedance tomography (EIT) is a bedside tool for lung ventilation and perfusion assessment. However, the ability for long-term monitoring diminished due to interferences from clinical interventions and motion artifacts. The purpose of this study is to investigate the feasibility of the discrete wavelet transform (DWT) to detect and remove the common types of motion artifacts in thoracic EIT.

methodsBaseline drifting, step-like and spike-like interferences were simulated to mimic three common types of motion artifacts. The discrete wavelet decomposition was employed to characterize those motion artifacts in different frequency levels with different wavelet coefficients, and those motion artifacts were then attenuated by suppressing the relevant wavelet coefficients. Further validation was conducted in two patients when motion artifacts were introduced through pulsating mattress and deliberate body movements. The db8 wavelet was used to decompose the contaminated signals into several sublevels.

resultsIn the simulation study, it was shown that, after being processed by DWT, the signal consistency improved by 92.98% for baseline drifting, 97.83% for the step-like artifact, and 62.83% for the spike-like artifact; the signal similarity improved by 77.49% for baseline drifting, 73.47% for the step-like artifact, and 2.35% for the spike-like artifact. Results from patient data demonstrated the EIT image errors decreased by 89.24% (baseline drifting), 88.45% (step-like artifact), and 97.80% (spike-like artifact), respectively; the data correlations between EIT images without artifacts and the processed were all > 0.95.

conclusionThis study found that DWT is a universal and effective tool to detect and remove these motion artifacts.

Indexed as

acute respiratory distress syndromechronic obstructive pulmonary diseasediscrete wavelet transformmotion artifactsthoracic electrical impedance tomography

Identifiers

PMID35174192
PMCPMC8841770