Evidence map›Paper›PMID 35173261›Full record

ArticleScientific reports2022

A suspended polymeric microfluidic sensor for liquid flow rate measurement in microchannels.

Fatemeh Mohammadamini, Javad Rahbar Shahrouzi, Mitra Samadi

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Fatemeh MohammadaminiFaculty of Chemical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran.
Javad Rahbar ShahrouziFaculty of Chemical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran. shahrouzi@sut.ac.ir.
Mitra SamadiFaculty of Chemical Engineering, Sahand University of Technology, Sahand New Town, Tabriz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, a microfluidic cantilever flow sensor was designed and manufactured to monitor liquid flow rate within the range of 100-1000 µl/min. System simulation was also performed to determine the influential optimal parameters and compare the results with experimental data. A flowmeter was constructed as a curved cantilever with dimensions of 6.9 × 0.5 × 0.6 mm

Identifiers

PMID35173261
PMCPMC8850574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.