What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 22 citations in OpenAlex.
- Dual Plating and Dorsal Bridge Plating for Comminuted Distal Radius Fractures: A Systematic Review.Journal of clinical medicine · 2026Review
- Observational
- Role of Intraoperative 2D and 3D Fluoroscopy in Identifying Malposition of Screws in Surgical Fixation of Intra-articular Distal Radius Fractures in Comparison to Post-operative Computed Tomography.Journal of orthopaedic case reports · 2026Article
- ESTES recommendations regarding distal radius fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Review
- Article
- Article
- A Comparison of Intraoperative 3D and Conventional 2D Fluoroscopy to Detect Screw Misplacement in Volar Plate Osteosynthesis of the Distal Radius.Journal of clinical medicine · 2025Article
- The Intraoperative Dorsal Tangential and the Radial Groove View of the Distal Radius to Detect Dorsal Screw Protrusion in Volar Plating: Teaching Effect and Value in Clinical Practice.Journal of hand surgery global online · 2025Article
- Return to Work After Subcutaneous Transposition of the Extensor Indicis Proprius to Repair Inveterate Ruptures of Extensor Pollicis Longus.Journal of clinical medicine · 2025Article
- A Case Report of Extensor Pollicis Longus Tendon Rupture: Delayed Diagnosis in a Professional Rugby Player.Cureus · 2024Article
- [Application of improved carpal shoot through view in volar plate internal fixation of distal radius fractures].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- Complications after volar plate synthesis for distal radius fractures.EFORT open reviews · 2024Article
- Management of extensor tendon injuries concerning distal radius fractures.Journal of orthopaedics · 2024Article
- CT-Based Micromotion Analysis After Locking Plate Fixation of AO Type C Distal Radius Fractures.Indian journal of orthopaedics · 2023Article
- Anatomic Risks with Overpenetration of the Volar Locking Plates' Proximal Holes.Journal of wrist surgery · 2023Article
- Acute bilateral extensor pollicis longus tendon rupture following bilateral displaced distal radius fracture: A case report.Acta orthopaedica et traumatologica turcica · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Distal radius fractures are common orthopedic injuries. Treatment has varied historically, but volar locking plating currently predominates. Although flexor tendon injury is a well-studied complication of this operation, extensor tendon injury is less well studied. The purpose of this review is to search the literature and present the epidemiology, presentation, and treatment of this complication. The Cochrane, EMBASE, PubMed, and SCOPUS databases were searched for the terms "volar" + "radius" + ("plate" OR "plating") + "extensor." Ninety final studies were included for analysis in this review. The incidence of extensor tendon rupture varies from 0% to 12.5%; the extensor pollicis longus is most commonly ruptured. The presentation and management of extensor tendon injury after injury, intraoperatively, and postoperatively are summarized. Radiographic views are described to detect screw prominence and minimize intraoperative risk. Extensor tendon injury after volar locking plate for distal radius fractures is an uncommon injury with several risk factors including dorsal screw prominence and fracture fragments. Removal of hardware and tendon transfers or reconstruction may be necessary to prevent loss of extensor mechanism.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.