Evidence map›Paper›PMID 35168366›Full record

ArticleBone & joint research2022

Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture : a finite element analysis.

Chang-Ho Jung, Yonghan Cha, Ha Seung Yoon, Chan Ho Park, Jun-Il Yoo, Jung-Taek Kim, Yongho Jeon

Abstract read
In one paragraph

Article in Bone & joint research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Biomechanical evaluation of percutaneous compression plate and femoral neck system in Pauwels type III femoral neck fractures.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Observational
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chang-Ho JungDepartment of Mechanical Engineering, Ajou University, Suwon, South Korea.
Yonghan ChaDepartment of Orthopaedic Surgery, Eulji University Hospital, Daejeon, South Korea.
Ha Seung YoonDepartment of Orthopaedic Surgery, Ajou University School of Medicine, Ajou Medical Center, Suwon, South Korea.
Chan Ho ParkDepartment of Orthopaedic Surgery, Yeungnam University Medical Center, Daegu, South Korea.ORCID 0000-0003-0409-8132
Jun-Il YooDepartment of Orthopaedic Surgery, Gyeongsang National University Hospital, Jinju, South Korea.
Jung-Taek KimDepartment of Orthopaedic Surgery, Ajou University School of Medicine, Ajou Medical Center, Suwon, South Korea.
Yongho JeonDepartment of Mechanical Engineering, Ajou University, Suwon, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsIn this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures.

methodsFinite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load.

resultsUnder a load of single-leg stance, Pauwels type III femoral neck fractures fixed with 10 mm shorter bolts revealed a 7% increase of the interfragmentary gap. The interfragmentary sliding, compressive, and shear stress remained similar to models with bolt tips positioned close to the subchondral bone. Inferior positioning of FNS provided a similar interfragmentary distance, but with 6% increase of the interfragmentary sliding distance compared to central positioning of bolts. Inferior positioning resulted in a one-third increase in interfragmentary compressive and shear stress. A 5 mm gap placed between the diaphysis and plate provided stability comparable to standard fixation, with a 7% decrease of interfragmentary gap and sliding distance, but similar compressive and shear stress.

conclusionFinite element analysis with FNS on Pauwels type III femoral neck fractures revealed that placement of the bolt tip close to subchondral bone provides increased stability. Inferior positioning of FNS bolt increased interfragmentary sliding distance, compressive, and shear stress. The comparable stability of the fixation model with the standard model suggests that a 5 mm gap placed between the plate and diaphysis could viably adjust the depth of the bolt. Cite this article:

Indexed as

CT scansdiaphysisfemoral headsFemoral NeckFemoral neck fracturefemoral neck fracturesFemoral neck systemFemurfinite element analysisFinite element analysisfinite elements modelsstable fixationsubchondral bone

Identifiers

PMID35168366
PMCPMC8882323

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.