Evidence map›Paper›PMID 35166942›Full record

ArticleClinical oral investigations2022

Impact of metal artefacts on subjective perception of image quality of 13 CBCT devices.

Victor Aquino Wanderley, Andre Ferreira Leite, Karla de Faria Vasconcelos, Ruben Pauwels, Francisca Müller-García, Kathrin Becker, Matheus L Oliveira, Reinhilde Jacobs

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Victor Aquino WanderleyOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium. victoraquinow@gmail.com.ORCID http://orcid.org/0000-0003-2528-7338
Andre Ferreira LeiteOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.ORCID http://orcid.org/0000-0002-7803-4740
Karla de Faria VasconcelosOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.ORCID http://orcid.org/0000-0002-0351-3683
Ruben PauwelsAarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark.ORCID http://orcid.org/0000-0002-9462-7546
Francisca Müller-GarcíaOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.ORCID http://orcid.org/0000-0002-4244-7850
Kathrin BeckerDepartment of Orthodontics, Universitätsklinikum Düsseldorf, Düsseldorf, Germany.ORCID http://orcid.org/0000-0003-1936-4683
Matheus L OliveiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.ORCID http://orcid.org/0000-0002-8054-8759
Reinhilde JacobsOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.ORCID http://orcid.org/0000-0002-3461-0363

Funding

coordenação de aperfeiçoamento de pessoal de nível superior 001
6 · The paper itself

Abstract

objectivesThe overall objective of this study was to assess how metal artefacts impact image quality of 13 CBCT devices. As a secondary objective, the influence of scanning protocols and field of view on CBCT image quality with and without metal artefacts was also assessed. MATERIALS AND

methodsCBCT images were acquired of a dry human skull phantom considering three clinical simulated conditions: one without metal and two with metallic materials (metallic pin and implant). An industrial micro-CT was used as a reference to register the CBCT images. Afterwards, four observers evaluated 306 representative image slices from 13 devices, ranking them from best to worst. Furthermore, within each device, medium FOV and small FOV standard images were compared. General linear mixed models were used to assess subjective perception of examiners on overall image quality in the absence and presence of metal-related artefacts (p < 0.05).

resultsImage quality perception significantly differed amongst CBCT devices (p < 0.05). Some devices performed significantly better, independently of scanning protocol and clinical condition. In the presence of metal artefacts, medium FOV standard scanning protocols scored significantly better, while in the absence of metal, small FOV standard yielded the highest performance.

conclusionsSubjective image quality differs significantly amongst CBCT devices and scanning protocols. Metal-related artefacts may highly impact image quality, with a significant device-dependent variability and only few scanners being more robust against metal artefacts. Often, metal artefact expression may be somewhat reduced by proper protocol selection. CLINICAL RELEVANCE: Metallic objects may severely impact image quality in several CBCT devices.

Indexed as

ArtifactsSpiral Cone-Beam Computed TomographyCone-Beam Computed TomographyHumansMetalsPerceptionPhantoms, ImagingMetalsArtefactsCone-beam computed tomographyImplantJaw boneQuality indicators

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.