ArticleJournal of medical Internet research2022
The Use of Wearable Pulse Oximeters in the Prompt Detection of Hypoxemia and During Movement: Diagnostic Accuracy Study.
Article in Journal of medical Internet research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- You Can't Be With Your Patients All the Time-Patient and Staff Views of a Wearable Vital Signs Monitoring System.Journal of advanced nursing · 2026Article
- Prediction of acute mountain sickness occurring at 4554 m using overnight pulse oximetry from lower altitude: A pilot study.Experimental physiology · 2026Article
- Clinical Evaluation of a Real-Time Wearable System for Monitoring In-Hospital Ambulatory Patients With COVID-19: Retrospective Data Study.JMIR medical informatics · 2026Article
- Performance of Wearable Pulse Oximetry During Controlled Hypoxia Induction: Instrument Validation Study.JMIR formative research · 2026Article
- Telemedicine in chronic lung disease management: progress and prospects.The Korean journal of internal medicine · 2026Review
- Heart Rate as a Predictor of 6-Month Pneumonia Risk in Patients With Dysphagia.Laryngoscope investigative otolaryngology · 2025Article
- Wearables in Chronomedicine and Interpretation of Circadian Health.Diagnostics (Basel, Switzerland) · 2025Review
- Article
- Evaluating AI Methods for Pulse Oximetry: Performance, Clinical Accuracy, and Comprehensive Bias Analysis.Bioengineering (Basel, Switzerland) · 2024Article
- The 2023 wearable photoplethysmography roadmap.Physiological measurement · 2023Review
- Evaluating blood oxygen saturation measurements by popular fitness trackers in postoperative patients: A prospective clinical trial.iScience · 2023Article
- Evaluation of Leading Smartwatches for the Detection of Hypoxemia: Comparison to Reference Oximeter.Sensors (Basel, Switzerland) · 2023Article
- Embodied strategies for public speaking anxiety: evaluation of the Corp-Oral program.Frontiers in human neuroscience · 2023Article
- A Real-Time Wearable System for Monitoring Vital Signs of COVID-19 Patients in a Hospital Setting.Frontiers in digital health · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCommercially available wearable (ambulatory) pulse oximeters have been recommended as a method for managing patients at risk of physiological deterioration, such as active patients with COVID-19 disease receiving care in hospital isolation rooms; however, their reliability in usual hospital settings is not known.
objectiveWe report the performance of wearable pulse oximeters in a simulated clinical setting when challenged by motion and low levels of arterial blood oxygen saturation (SaO
methodsThe performance of 1 wrist-worn (Wavelet) and 3 finger-worn (CheckMe O2+, AP-20, and WristOx2 3150) wearable, wireless transmission-mode pulse oximeters was evaluated. For this, 7 motion tasks were performed: at rest, sit-to-stand, tapping, rubbing, drinking, turning pages, and using a tablet. Hypoxia exposure followed, in which inspired gases were adjusted to achieve decreasing SaO
resultsSpO
conclusionsThe SpO
trial registrationISRCTN Registry 61535692; http://www.isrctn.com/ISRCTN61535692. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2019-034404.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.