Evidence map›Paper›PMID 35165490›Full record

ArticleBeijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences2022

[Preliminary clinical application verification of complete digital workflow of design lips symmetry reference plane based on posed smile].

S T Qiu, Y J Zhu, S M Wang, F L Wang, H Q Ye, Y J Zhao, Y S Liu, Y Wang, Y S Zhou

Abstract read
In one paragraph

Article in Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

S T QiuDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Y J ZhuDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
S M WangCenter of Dental Laboratory, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
F L WangDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
H Q YeDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Y J ZhaoDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Y S LiuDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Y WangDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Y S ZhouDepartment of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design.

methodsEighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application.

resultsThe average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (

conclusionAutomatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.

Indexed as

LipToothEsthetics, DentalHumansSmilingWorkflowComputer-aided designDental estheticsFacial asymmetryImaging, three-dimensional

Identifiers

PMID35165490
PMCPMC8860648

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.