Evidence map›Paper›PMID 35165316›Full record

ArticleScientific reports2022

A machine learning-based on-demand sweat glucose reporting platform.

Devangsingh Sankhala, Abha Umesh Sardesai, Madhavi Pali, Kai-Chun Lin, Badrinath Jagannath, Sriram Muthukumar, Shalini Prasad

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
5.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 72 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Review
  8. Machine-Learning-Aided Advanced Electrochemical Biosensors.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Devangsingh Sankhala *Department of Electrical Engineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA.
Abha Umesh Sardesai *Department of Computer Engineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA.
Madhavi Pali *Department of Bioengineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA.
Kai-Chun Lin *Department of Bioengineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA.
Badrinath Jagannath *Department of Bioengineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA.
Sriram MuthukumarEnLiSense LLC, 1813 Audubon Pond Way, Allen, TX, 75013, USA.
Shalini PrasadDepartment of Computer Engineering, The University of Texas at Dallas, 800 W Campbell Rd, Richardson, TX, 75080, USA. shalini.prasad@utdallas.edu.
The University of Texas at Dallas · USNational Audubon Society · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Diabetes is a chronic endocrine disease that occurs due to an imbalance in glucose levels and altering carbohydrate metabolism. It is a leading cause of morbidity, resulting in a reduced quality of life even in developed societies, primarily affected by a sedentary lifestyle and often leading to mortality. Keeping track of blood glucose levels noninvasively has been made possible due to diverse breakthroughs in wearable sensor technology coupled with holistic digital healthcare. Efficient glucose management has been revolutionized by the development of continuous glucose monitoring sensors and wearable, non/minimally invasive devices that measure glucose concentration by exploiting different physical principles, e.g., glucose oxidase, fluorescence, or skin dielectric properties, and provide real-time measurements every 1-5 min. This paper presents a highly novel and completely non-invasive sweat sensor platform technology that can measure and report glucose concentrations from passively expressed human eccrine sweat using electrochemical impedance spectroscopy and affinity capture probe functionalized sensor surfaces. The sensor samples 1-5 µL of sweat from the wearer every 1-5 min and reports sweat glucose from a machine learning algorithm that samples the analytical reference values from the electrochemical sweat sensor. These values are then converted to continuous time-varying signals using the interpolation methodology. Supervised machine learning, the decision tree regression algorithm, shows the goodness of fit R

Indexed as

Supervised Machine LearningAdolescentAdultBiomarkersBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringCohort StudiesDiabetes MellitusDielectric SpectroscopyEccrine GlandsElectrochemical TechniquesHealthy VolunteersHumansSweatWearable Electronic DevicesBiomarkersBlood Glucose

Identifiers

PMID35165316
PMCPMC8844049
OpenAlexW4213106821

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.