Evidence map›Paper›PMID 35161997›Full record

ReviewSensors (Basel, Switzerland)2022

Respiratory Monitoring by Ultrafast Humidity Sensors with Nanomaterials: A Review.

Shinya Kano, Nutpaphat Jarulertwathana, Syazwani Mohd-Noor, Jerome K Hyun, Ryota Asahara, Harutaka Mekaru

Open access · goldAbstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
5.9field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 68 citations in OpenAlex.

  1. Review
  2. Review
  3. Liquid Metal-Enabled Soft Bioelectronics for Human Health Monitoring.Small (Weinheim an der Bergstrasse, Germany) · 2026
    Review
  4. Article
  5. Review
  6. Article
  7. Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing.IEEE reviews in biomedical engineering · 2025
    Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Shinya KanoHuman Augmentation Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Kashiwa 277-0882, Japan.ORCID 0000-0001-8117-5838
Nutpaphat JarulertwathanaDepartment of Chemistry and Nanoscience, Ewha Womans University, Seoul 03760, Korea.ORCID 0000-0003-3335-8060
Syazwani Mohd-NoorDepartment of Chemistry and Nanoscience, Ewha Womans University, Seoul 03760, Korea.
Jerome K HyunDepartment of Chemistry and Nanoscience, Ewha Womans University, Seoul 03760, Korea.
Ryota AsaharaHuman Informatics and Interaction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8566, Japan.ORCID 0000-0002-0861-0861
Harutaka MekaruHuman Augmentation Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Kashiwa 277-0882, Japan.ORCID 0000-0002-1120-6018
Ewha Womans University · KRNational Institute of Advanced Industrial Science and Technology · JP

Funding

Japan Society for the Promotion of Science 18KK0141, Funding of Leading Initiative for Excellent Young ResearchersMinistry of Science ICT and Future Planning NRF-2017R1A5A1015365
6 · The paper itself

Abstract

Respiratory monitoring is a fundamental method to understand the physiological and psychological relationships between respiration and the human body. In this review, we overview recent developments on ultrafast humidity sensors with functional nanomaterials for monitoring human respiration. Key advances in design and materials have resulted in humidity sensors with response and recovery times reaching 8 ms. In addition, these sensors are particularly beneficial for respiratory monitoring by being portable and noninvasive. We systematically classify the reported sensors according to four types of output signals: impedance, light, frequency, and voltage. Design strategies for preparing ultrafast humidity sensors using nanomaterials are discussed with regard to physical parameters such as the nanomaterial film thickness, porosity, and hydrophilicity. We also summarize other applications that require ultrafast humidity sensors for physiological studies. This review provides key guidelines and directions for preparing and applying such sensors in practical applications.

Indexed as

NanostructuresHumansHumidityMonitoring, PhysiologicPorosityRespirationfast responsehumidity sensornanomaterialphysiological monitoringrespiratory monitoring

Identifiers

PMID35161997
PMCPMC8838830
OpenAlexW4210832078

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.