Evidence map›Paper›PMID 35161774›Full record

ArticleSensors (Basel, Switzerland)2022

Self-Calibration Method and Pose Domain Determination of a Light-Pen in a 3D Vision Coordinate Measurement System.

Dongri Shan, Chenglong Zhang, Peng Zhang, Xiaofang Wang, Dongmei He, Yalu Xu, Maohui Zhou, Guoqi Yu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Dongri ShanSchool of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.ORCID 0000-0003-2340-596X
Chenglong ZhangSchool of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Peng ZhangSchool of Electrical Engineering and Automation, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Xiaofang WangSchool of Electrical Engineering and Automation, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Dongmei HeSchool of Electrical Engineering and Automation, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Yalu XuSchool of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Maohui ZhouSchool of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Guoqi YuSchool of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250300, China.
Qilu University of Technology · CN

Funding

the Natural Science Foundation of Shandong Province of China No.ZR2020MF138.the Project of 20 Policies of Facilitate Scientific Research in Jinan Colleges No.2019GXRC063the Project of Shandong Province Higher Educational Science and Technology Program No.J18KA345the Project of Shandong Provincial Major Scientific and Technological Innovation No.2019JZZY010444the Project of Shandong Provincial Major Scientific and Technological Innovation No.2019TSLH0315
6 · The paper itself

Abstract

Light pens for 3D vision coordinate measurement systems are increasingly widely used due to their advantages, such as their small size, convenience of being carried, and widespread applicability. The posture of the light pen is an important factor that affects accuracy. The pose domain of the pen needs to be given so that the measurement system has a suitable measurement range to obtain more qualified parameters. The advantage of the self-calibration method is that the entire self-calibration process can be completed at the measurement site with no auxiliary equipment. After the system camera calibration was completed, we took several pictures of the same measurement point with different poses to obtain the conversion matrix of the picture and subsequently used spherical fitting, the generalized inverse method of least squares, and the principle of position invariance in the pose domain range. The combined stylus tip center self-calibration method calculates the actual position of the light pen probe. The experimental results verify the effectiveness of the method; the measurement accuracy of the system can satisfy basic industrial measurement requirements.

Indexed as

PostureCalibrationpose domainspherical fittingstylus tip center self-calibrationvision measurement system

Identifiers

PMID35161774
PMCPMC8838791
OpenAlexW4210580184

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.