Evidence map›Paper›PMID 35161530›Full record

ArticleSensors (Basel, Switzerland)2022

A Single Sacral-Mounted Inertial Measurement Unit to Estimate Peak Vertical Ground Reaction Force, Contact Time, and Flight Time in Running.

Aurélien Patoz, Thibault Lussiana, Bastiaan Breine, Cyrille Gindre, Davide Malatesta

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Aurélien PatozInstitute of Sport Sciences, University of Lausanne, 1015 Lausanne, Switzerland.
Thibault LussianaVolodalen Swiss Sport Lab, Research and Development Department, 1860 Aigle, Switzerland.ORCID 0000-0002-1782-401X
Bastiaan BreineVolodalen Swiss Sport Lab, Research and Development Department, 1860 Aigle, Switzerland.
Cyrille GindreVolodalen Swiss Sport Lab, Research and Development Department, 1860 Aigle, Switzerland.
Davide MalatestaInstitute of Sport Sciences, University of Lausanne, 1015 Lausanne, Switzerland.ORCID 0000-0003-3905-5642
University of Lausanne · CHGhent University · BEUniversité de franche-comté · FR

Funding

Innosuisse - Swiss Innovation Agency 35793.1 IP-LS
6 · The paper itself

Abstract

Peak vertical ground reaction force (Fz,max), contact time (tc), and flight time (tf) are key variables of running biomechanics. The gold standard method (GSM) to measure these variables is a force plate. However, a force plate is not always at hand and not very portable overground. In such situation, the vertical acceleration signal recorded by an inertial measurement unit (IMU) might be used to estimate Fz,max, tc, and tf. Hence, the first purpose of this study was to propose a method that used data recorded by a single sacral-mounted IMU (IMU method: IMUM) to estimate Fz,max. The second aim of this study was to estimate tc and tf using the same IMU data. The vertical acceleration threshold of an already existing IMUM was modified to detect foot-strike and toe-off events instead of effective foot-strike and toe-off events. Thus, tc and tf estimations were obtained instead of effective contact and flight time estimations. One hundred runners ran at 9, 11, and 13 km/h. IMU data (208 Hz) and force data (200 Hz) were acquired by a sacral-mounted IMU and an instrumented treadmill, respectively. The errors obtained when comparing Fz,max, tc, and tf estimated using the IMUM to Fz,max, tc, and tf measured using the GSM were comparable to the errors obtained using previously published methods. In fact, a root mean square error (RMSE) of 0.15 BW (6%) was obtained for Fz,max while a RMSE of 20 ms was reported for both tc and tf (8% and 18%, respectively). Moreover, even though small systematic biases of 0.07 BW for Fz,max and 13 ms for tc and tf were reported, the RMSEs were smaller than the smallest real differences [Fz,max: 0.28 BW (11%), tc: 32.0 ms (13%), and tf: 32.0 ms (30%)], indicating no clinically important difference between the GSM and IMUM. Therefore, these results support the use of the IMUM to estimate Fz,max, tc, and tf for level treadmill runs at low running speeds, especially because an IMU has the advantage to be low-cost and portable and therefore seems very practical for coaches and healthcare professionals.

Indexed as

RunningAccelerationBiomechanical PhenomenaFootGaitMechanical Phenomenaaccelerometerbiomechanicsgait analysissensor

Identifiers

PMID35161530
PMCPMC8838733
OpenAlexW4206697265

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.