Evidence map›Paper›PMID 35161506›Full record

ArticleSensors (Basel, Switzerland)2022

Characterization of Open-Ended Coaxial Probe Sensing Depth with Respect to Aperture Size for Dielectric Property Measurement of Heterogeneous Tissues.

Cemanur Aydinalp, Sulayman Joof, Ismail Dilman, Ibrahim Akduman, Tuba Yilmaz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. [Study on the difference of high frequency dielectric properties of biological tissues measured by air and packed coaxial probe].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Cemanur AydinalpDepartment of Electronics and Communication Engineering, Istanbul Technical University, Istanbul 34469, Turkey.ORCID 0000-0002-3070-6202
Sulayman JoofDepartment of Electronics and Communication Engineering, Istanbul Technical University, Istanbul 34469, Turkey.ORCID 0000-0002-6432-9951
Ismail DilmanDepartment of Electronics and Communication Engineering, Istanbul Technical University, Istanbul 34469, Turkey.ORCID 0000-0003-1500-2263
Ibrahim AkdumanDepartment of Electronics and Communication Engineering, Istanbul Technical University, Istanbul 34469, Turkey.ORCID 0000-0002-5769-6032
Tuba YilmazDepartment of Electronics and Communication Engineering, Istanbul Technical University, Istanbul 34469, Turkey.ORCID 0000-0003-3052-2945

Funding

COST Action CA17115Scientific and Technological Research Council of Turkey 118S074
6 · The paper itself

Abstract

The open-ended coaxial probe (OECP) method is frequently used for the microwave dielectric property (DP) characterization of high permittivity and conductivity materials due to inherent advantages including minimal sample preparation requirements and broadband measurement capabilities. However, the OECP method is known to suffer from high measurement error. One well-known contributor to the high error rates is tissue heterogeneity, which can potentially be managed through the selection of a probe with a proper sensing depth (SD). The SD of the OECP is dependent on many factors including sample DPs and probe aperture diameter. Although the effects of sample DPs on SD have been investigated to some extent in the literature, the probe aperture diameters, particularly small diameters, have not been fully explored. To this end, the SDs of probes with three different apertures (0.5, 0.9 and 2.2 mm-diameters) were analyzed in this study. Probes' SDs were first investigated with simulations using a double-layered sample configuration (skin tissue and olive oil). Next, experiments were performed using a commercial OECP with a 2.2 mm aperture diameter. The SD was categorized based on 5%, 20% and 80% DP change. Among these threshold values, a 5% DP change was selected as the benchmark for SD categorization. The findings suggest that probes with a smaller aperture size and correspondingly smaller SD should be utilized when measuring the DPs of thin and multilayered samples, such as healthy and diseased skin tissues, to increase the measurement accuracy.

Indexed as

SkinElectric Conductivitybroadband dielectric property retrievaldielectric property measurementopen-ended coaxial probephantom materialssensing depthskin tissue

Identifiers

PMID35161506
PMCPMC8839841

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.