Evidence map›Paper›PMID 35160873›Full record

ArticleMaterials (Basel, Switzerland)2022

Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial.

Lorenzo Arcuri, Fabrizio Lio, Veronica Campana, Vincenzo Mazzetti, Francesca Romana Federici, Alessandra Nardi, Massimo Galli

Registry-linked trialAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05985226 (Clinical Evaluation of the Effect of the Scanning Pattern on Complete-arch Implant Scans), which is not on this map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05985226 naunknown statusnot on this mapstarted 2023, after this paper: background citation

Clinical Evaluation of the Effect of the Scanning Pattern on Complete-arch Implant Scans

TypeinterventionalSponsorUniversidad Complutense de MadridRan2023 to 2023Enrolled1ConditionsDental Prosthesis, Implant-SupportedArmsintraoral scan
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lorenzo ArcuriMaterials for Health, Environment and Energy, University of Rome Tor Vergata, 00133 Rome, Italy.
Fabrizio LioMaterials for Health, Environment and Energy, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0001-7071-3127
Veronica CampanaIndependent Researcher, 20121 Milan, Italy.ORCID 0000-0003-1676-3419
Vincenzo MazzettiMaterials for Health, Environment and Energy, University of Rome Tor Vergata, 00133 Rome, Italy.
Francesca Romana FedericiInnovative Technologies in Skeletal, Skin and Oro-Cranio-Facial Diseases, Sapienza University of Rome, 00185 Rome, Italy.
Alessandra NardiDepartment of Mathematics, University of Rome Tor Vergata, 00133 Rome, Italy.
Massimo GalliDepartment of Dental and Maxillofacial Sciences, Sapienza University of Rome, 00185 Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to evaluate the influence of implant scanbody (ISB) wear on the accuracy of digital impression for complete-arch. A polymethylmethacrylate (PMMA) edentulous mandibular model with four internal hexagonal interlocking conical connections was scanned with an extraoral optical scanner to achieve a reference file. Four cylindrical polyetheretherketone (PEEK) ISBs were scanned 30 times with IOS, and the test files were aligned to the reference file with a best-fit algorithm. For each analog linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Euclidean distance (ΔEUC) was calculated from the linear deviation, reporting a mean of 82 µm (SD 61) ranging from 8 to 347 µm. ΔANGLE error mean was 0.33° (SD 0.20), ranging from 0.02 to 0.92°. From a multivariate analysis, when ΔEUC was considered as a response variable, a significant influence of ISB wear by scan number in interaction to position for implant 3.6 was identified (

Indexed as

accuracycomplete archdigital impressionintraoral optical scanningscanbodywear

Identifiers

PMID35160873
PMCPMC8838002

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.