ArticleCureus2022
Treatment of Basicervical Femoral Fracture With Retractable Talon Hip Compression Screw.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Basicervical femoral fractures (BFFs) are rare and biomechanically unstable. The goal of this study was to evaluate the effectiveness of the Talon™ DistalFix™ (Orthopedic Designs North America, Inc., Tampa, FL, USA) nail for the treatment of BFFs with a novel design. Methodology In this retrospective study, 25 patients with BFFs were analyzed between January 2016 and March 2020 at our institute. All patients were treated with the Talon™ DistalFix™ nail. Patients over the age of 60 years with basicervical fractures caused by low-energy trauma were included in this study. For inclusion into the study, the minimum follow-up time had to be longer than six months. The postoperative radiographic bone union, operative time, tip-apex distance (TAD), sliding distance of the lag screw, quality of fracture reduction, and major complications such as cut-out, non-union of the fracture, femoral head collapse, and cut-through were recorded. The Harris Hip Score was used to evaluate hip function at the end of the follow-up period. Results The mean follow-up period was 22 months (range, 16-28 months), and the mean age was 77.8 years (range, 61-91 years). The average sliding distance of the lag screw was 5.7 mm (range, 0.2-13.1 mm). The mean TAD of immediate postoperative view was 20.8 mm (range, 18.7-23.7 mm), and the TAD was <25 mm in all cases. Radiographic union was confirmed in most cases, and the average time for radiographic union was 18.8 weeks (range, 12-25 weeks). Most fractures (90.5%) had healed with no postoperative mechanical complications (cut-out, cut-thorough, or lateral wall fracture) at the final follow-up, except for two patients. One of the two patients had no evidence of union at six months, and mild varus reduction was observed in the other patient who had shortening of >10 mm. Conclusions According to the clinical and radiological findings of this study, treatment with the Talon™ DistalFix™ nail showed satisfactory results. Hence, it can be a suitable option in the treatment of BFFs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.