Evidence map›Paper›PMID 35149703›Full record

ArticleScientific reports2022

Virtual monoenergetic micro-CT imaging in mice with artificial intelligence.

Brent van der Heyden, Stijn Roden, Rüveyda Dok, Sandra Nuyts, Edmond Sterpin

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. LED-based optoacoustic tomography of mice.Journal of biomedical optics · 2025
    Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Brent van der HeydenDepartment of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium.ORCID 0000-0001-8412-6417
Stijn RodenDepartment of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium.
Rüveyda DokDepartment of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium.
Sandra NuytsDepartment of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium.
Edmond SterpinDepartment of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven, Leuven, Belgium. edmond.sterpin@kuleuven.be.
KU Leuven · BEMolecular Oncology (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Micro cone-beam computed tomography (µCBCT) imaging is of utmost importance for carrying out extensive preclinical research in rodents. The imaging of animals is an essential step prior to preclinical precision irradiation, but also in the longitudinal assessment of treatment outcomes. However, imaging artifacts such as beam hardening will occur due to the low energetic nature of the X-ray imaging beam (i.e., 60 kVp). Beam hardening artifacts are especially difficult to resolve in a 'pancake' imaging geometry with stationary source and detector, where the animal is rotated around its sagittal axis, and the X-ray imaging beam crosses a wide range of thicknesses. In this study, a seven-layer U-Net based network architecture (vMonoCT) is adopted to predict virtual monoenergetic X-ray projections from polyenergetic X-ray projections. A Monte Carlo simulation model is developed to compose a training dataset of 1890 projection pairs. Here, a series of digital anthropomorphic mouse phantoms was derived from the reference DigiMouse phantom as simulation geometry. vMonoCT was trained on 1512 projection pairs (= 80%) and tested on 378 projection pairs (= 20%). The percentage error calculated for the test dataset was 1.7 ± 0.4%. Additionally, the vMonoCT model was evaluated on a retrospective projection dataset of five mice and one frozen cadaver. It was found that beam hardening artifacts were minimized after image reconstruction of the vMonoCT-corrected projections, and that anatomically incorrect gradient errors were corrected in the cranium up to 15%. Our results disclose the potential of Artificial Intelligence to enhance the µCBCT image quality in biomedical applications. vMonoCT is expected to contribute to the reproducibility of quantitative preclinical applications such as precision irradiations in X-ray cabinets, and to the evaluation of longitudinal imaging data in extensive preclinical studies.

Indexed as

Artificial IntelligenceCone-Beam Computed TomographyAnimalsArtifactsCadaverImage Processing, Computer-AssistedMiceMonte Carlo MethodNeural Networks, ComputerPhantoms, ImagingRetrospective Studies

Identifiers

PMID35149703
PMCPMC8837804
OpenAlexW4211226373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.