ArticleBMC musculoskeletal disorders2022
Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.
- Comparison between arthroscopic surgery and open reduction internal fixation in patients with posterior cruciate ligament tibial avulsion fracture: a systematic review with meta-analysis.BMC musculoskeletal disorders · 2026Pooled it
- Article
- Arthroscopic Management of Posterior Cruciate Ligament Avulsion Fractures Utilizing Anterior Compartment Loop-and-Tack Suspension Fixation.Orthopaedic journal of sports medicine · 2025Article
- Classification and Bundle-Weaving Fixation for Posterior Cruciate Ligament Tibial Avulsion Fractures: Innovations and Applications of Key Techniques.Orthopaedic surgery · 2025Article
- Stepping into the Unknown: Unveiling the Rarity of PCL Fracture-Avulsions.Trauma case reports · 2024Article
- Biomechanical study of posterior cruciate ligament tibial arrest avulsion fracture fixation with triple tibial channel net sutures.Scientific reports · 2023Article
- Systematic Review and Meta-analysis of Clinical Outcomes After Management of Posterior Cruciate Ligament Tibial Avulsion Fractures.Orthopaedic journal of sports medicine · 2023Review
- Application of CT-MRI Fusion-Based Three-Dimensional Reconstruction Technique in the Anatomic Study of Posterior Cruciate Ligament.Orthopaedic surgery · 2022Article
- Homemade pin-hook for surgical treatment of posterior cruciate ligament avulsion fractures.BMC musculoskeletal disorders · 2022Article
- Treatment of avulsion fracture of posterior cruciate ligament tibial insertion by minimally invasive approach in posterior medial knee.Frontiers in surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare the clinical results of homemade hook plates and hollow lag screws combined with spacers in the treatment of posterior cruciate tibial ligament avulsion fractures. MATERIALS AND
methodsThis was a retrospective clinical cohort study that included 64 patients with PCL tibial avulsion fractures. Thirty-two of them were fixed with a homemade hook plate (hook plate group), and 32 were fixed with a hollow lag screen combined with a gasket (hollow lag screen group). By reviewing the medical record data and follow-up results, the operation time, postoperative drainage, fracture healing time, surgical complications, knee mobility, recovery of joint function, and whether postoperative gastrocnemius muscle strength changed in the two groups were compared.
resultsAll patients had successful wound and fracture healing. No adverse events, such as bone nonunion, infection, wound haematoma, or joint stiffness, occurred in either group. There were no patients with decreased gastrocnemius muscle strength in either group. Internal fixation failure occurred in 2 cases in the hollow lag screen group but not in the hook plate group. There were no significant differences between the two groups in terms of operative time, postoperative drainage, fracture healing time, knee mobility at the last follow-up, or Lysholm score.
conclusionIt is safe and effective to use a homemade hook plate to fix PCL tibial avulsion fractures through an inverted L-shaped posterior medial approach. A homemade hook plate may have potential advantages over a hollow lag screen combined with gasket fixation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.