Evidence map›Paper›PMID 35148737›Full record

ArticleBMC musculoskeletal disorders2022

Open reduction and internal fixation of the tibial avulsion fracture of the posterior cruciate ligament: which is better, a hollow lag screw combined with a gasket or a homemade hook plate?

Hongfei Qi, Yao Lu, Ming Li, Cheng Ren, Yibo Xu, Teng Ma, Qian Wang, Kun Zhang, Zhong Li

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.0field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Hongfei Qi *Department of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Yao Lu *Department of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Ming Li *Department of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Cheng RenDepartment of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Yibo XuDepartment of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Teng Ma *Department of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Qian WangDepartment of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China. wangqian32846@163.com.
Kun ZhangDepartment of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China.
Zhong LiDepartment of Orthopaedics and Trauma, Hong Hui Hospital, Xi'an Jiaotong University College of Medicine, No. 555, East Youyi Road, Xi'an, 710000, Shaanxi, China. lizhong888882021@163.com.
Xi'an Jiaotong University · CNXi'an Honghui Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the clinical results of homemade hook plates and hollow lag screws combined with spacers in the treatment of posterior cruciate tibial ligament avulsion fractures. MATERIALS AND

methodsThis was a retrospective clinical cohort study that included 64 patients with PCL tibial avulsion fractures. Thirty-two of them were fixed with a homemade hook plate (hook plate group), and 32 were fixed with a hollow lag screen combined with a gasket (hollow lag screen group). By reviewing the medical record data and follow-up results, the operation time, postoperative drainage, fracture healing time, surgical complications, knee mobility, recovery of joint function, and whether postoperative gastrocnemius muscle strength changed in the two groups were compared.

resultsAll patients had successful wound and fracture healing. No adverse events, such as bone nonunion, infection, wound haematoma, or joint stiffness, occurred in either group. There were no patients with decreased gastrocnemius muscle strength in either group. Internal fixation failure occurred in 2 cases in the hollow lag screen group but not in the hook plate group. There were no significant differences between the two groups in terms of operative time, postoperative drainage, fracture healing time, knee mobility at the last follow-up, or Lysholm score.

conclusionIt is safe and effective to use a homemade hook plate to fix PCL tibial avulsion fractures through an inverted L-shaped posterior medial approach. A homemade hook plate may have potential advantages over a hollow lag screen combined with gasket fixation.

Indexed as

Fractures, AvulsionPosterior Cruciate LigamentTibial FracturesArthroscopyBone ScrewsCohort StudiesFracture Fixation, InternalHumansRetrospective StudiesTreatment OutcomeHomemade hook plateInternal fixationPCL tibial avulsion

Identifiers

PMID35148737
PMCPMC8840316
OpenAlexW4211060490

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.