Evidence map›Paper›PMID 35147713›Full record

ArticlePediatric radiology2022

Fetal magnetic resonance imaging at 3 Tesla - the European experience.

Gabrielle C Colleran, Martin Kyncl, Catherine Garel, Marie Cassart

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
7.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Advancements in MRI application in the morphological development of fetal cerebral venous system: a review.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2025
    Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Fetal MRI: what's new? A short review.European radiology experimental · 2023
    Review
  10. Review
  11. ISUOG Practice Guidelines (updated): performance of fetal magnetic resonance imaging.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2023
    Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 4 countries.

Gabrielle C ColleranDepartment of Radiology, National Maternity Hospital, Holles Street, Dublin 2, Ireland. gcolleran@nmh.ie.ORCID 0000-0002-1684-6671
Martin KynclDepartment of Radiology, Second Faculty of Medicine, Charles University and Motol University Hospital, Prague, Czech Republic.
Catherine GarelDepartment of Radiology, Hôpital d'Enfants Armand-Trousseau, AP-HP, Paris, France.
Marie CassartDepartment of Radiology and Fetal Medicine, Iris South Hospitals and CHU St Pierre, Brussels, Belgium.
Charles University · CZChildren's Health Ireland at Crumlin · IEHôpital Armand-Trousseau · FRHôpitaux Iris Sud · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Fetal Imaging Taskforce was established in 2018 by the European Society of Paediatric Radiology. The first survey on European practice of fetal imaging published in 2020 revealed that 30% of fetal magnetic resonance imaging (MRI) is performed at 3 tesla (T). The purpose of this second survey was to identify the impact of 3-T fetal MRI with an emphasis on image quality, diagnostic yield, and technical challenges and artifacts at higher field strengths.

objectiveTo describe the prenatal imaging practice at 3-T MRI units in various centres in Europe and to prepare recommendations on behalf of the Fetal Imaging Taskforce. MATERIALS AND

methodsA survey was sent to all members performing 3-T fetal MRI. Questions included practitioner experience, magnet brand, protocols, counselling, artifacts and benefits of imaging at higher field strengths.

resultsTwenty-seven centres replied and reported improved spatial resolution and improved signal-to-noise ratio when performing fetal MRI at 3 T. Shading and banding artifacts and susceptibility to motion artifacts were common problems identified by practitioners at the higher field strength. For all neurological indications, practitioners reported a benefit of imaging at 3 T, most marked for posterior fossa evaluation and parenchymal lesions.

conclusionThe use of 3-T magnets in fetal MRI has improved the availability and quality of advanced imaging sequences and allowed for better anatomical evaluation. There remain significant challenges to minimize the impact of artifacts on image quality. This paper includes guidelines for clinical practice and imaging at 3 T.

Indexed as

ArtifactsMagnetic Resonance ImagingChildFemaleFetusHumansMotionPregnancySignal-To-Noise Ratio3 TeslaArtifactsFetusGuidelinesIndicationsMagnetic resonance imaging

Identifiers

PMID35147713
OpenAlexW4210993438

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.