Evidence map›Paper›PMID 35147295›Full record

ArticleOrthopaedic surgery2022

Finite Element Analysis of a New Type of Spinal Protection Device for the Prevention and Treatment of Osteoporotic Vertebral Compression Fractures.

Mingxue Che, Yongjie Wang, Yao Zhao, Shaokun Zhang, Jun Yu, Weiquan Gong, Debao Zhang, Mingxi Liu

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Risk factors for adjacent vertebral fracture after kyphoplasty or percutaneous vertebroplasty in osteoporotic vertebral systematic review and meta-analysis compression fractures.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Mingxue CheDepartment of Spinal Surgery, The First Hospital of Jilin University, Changchun, China.
Yongjie WangDepartment of Spinal Surgery, The First Hospital of Jilin University, Changchun, China.ORCID https://orcid.org/0000-0001-6891-7892
Yao ZhaoDepartment of Joint Surgery, The First Hospital of Jilin University, Changchun, China.
Shaokun ZhangDepartment of Spinal Surgery, The First Hospital of Jilin University, Changchun, China.
Jun YuDepartment of medical imaging, Jilin Provincial Armed Police Corps Hospital, Changchun, China.
Weiquan GongDepartment of Spinal Surgery, The First Hospital of Jilin University, Changchun, China.
Debao ZhangDepartment of Joint Surgery, The First Hospital of Jilin University, Changchun, China.
Mingxi LiuDepartment of Orthopaedic Traumatology, The First Hospital of Jilin University, Changchun, China.
Jilin University · CNChinese People's Armed Police Force Medical College Affiliated Hospital · CN

Funding

Not applicable
6 · The paper itself

Abstract

objectiveTo study the effectiveness of a new spinal protection device for preventing and treating osteoporotic vertebral compression fractures (OVCFs) by finite element analysis (FEA).

methodsOne healthy volunteer and one patient with 1-segment lumbar vertebral compression fractures were included in this experimental study. The DICOM files of two different lumbar spiral computed tomography (CT) scans were converted into STL files, and 3D finite element models of the lumbar spine were generated for normal and L1 vertebral fracture spines. A new type of spinal protection device was applied to reduce the stress on the anterior vertebral edge and direct the center of gravity posteriorly. The stress distribution characteristics of different finite element models of the lumbar spine were analyzed, revealing the characteristics of the stress distributed along the spine under the action of the new spinal protection device.

resultsUnder normal conditions, the stress was mainly distributed in the middle and posterior columns of the spine. When the anterior border of the L1 vertebral body was fractured and collapsed, the stress distribution shifted toward the anterior column due to the center of gravity being directed forward. According to finite element analysis of the spine with the new protection device, the stress in the middle and posterior columns tended to increase, and that in the anterior column decreased. After the new type of spinal fixation device was applied, the stress at the L1 and L2 vertebral endplates decreased to a certain extent, especially that at the L1 vertebral body. The maximum stress on the L1 vertebral body decreased by 20% after the auxiliary device was applied.

conclusionsAccording to the FEA results, the new spinal protection device can effectively prevent and treat osteoporotic vertebral compression fractures (OVCFs), and can alter the stress distribution in the spine and reduce the stress in the anterior column of the vertebral body, especially in vertebral compression fractures.

Indexed as

Fractures, CompressionOsteoporotic FracturesSpinal FracturesFinite Element AnalysisHumansLumbar VertebraeFinite element analysisOsteoporosisOsteoporotic vertebral fractureSpinal protectionStress distribution

Identifiers

PMID35147295
PMCPMC8926982
OpenAlexW4211208887

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.