ArticleMilitary Medical Research2022
Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections.
Article in Military Medical Research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 28 citations in OpenAlex.
- Point of care sepsis diagnosis: Exploring microfluidic techniques for sample preparation, biomarker isolation, and detection.Biomicrofluidics · 2025Review
- AI-Powered Innovations in Food Safety from Farm to Fork.Foods (Basel, Switzerland) · 2025Review
- Nanozyme-Powered Multimodal Sensing for Pesticide Detection.Foods (Basel, Switzerland) · 2025Review
- Rapid and Differential Diagnosis of Sepsis Stages Using an Advanced 3D Plasmonic Bimetallic Alloy Nanoarchitecture-Based SERS Biosensor Combined with Machine Learning for Multiple Analyte Identification.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Microfluidic biosensors for biomarker detection in body fluids: a key approach for early cancer diagnosis.Biomarker research · 2024Review
- Progress in Procalcitonin Detection Based on Immunoassay.Research (Washington, D.C.) · 2024Review
- Manipulator Control System Based on Flexible Sensor Technology.Micromachines · 2023Review
- Structural Optimization Design of Microfluidic Chips Based on Fast Sequence Pair Algorithm.Micromachines · 2023Article
- Advances in Microfluidics Techniques for Rapid Detection of Pesticide Residues in Food.Foods (Basel, Switzerland) · 2023Review
- Study of Mechanical Response of Paper-Based Microfluidic System as a Potential Milk Tester.Micromachines · 2023Article
- Research on Integrated 3D Printing of Microfluidic Chips.Micromachines · 2023Article
- Effect of Flow Velocity on Laminar Flow in Microfluidic Chips.Micromachines · 2023Article
- Dual-Mode Sensing Platform for Cancer Antigen 15-3 Determination Based on a Silica Nanochannel Array Using Electrochemiluminescence and Electrochemistry.Biosensors · 2023Article
- Microfluidics-Based POCT for SARS-CoV-2 Diagnostics.Micromachines · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEarly diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements.
methodsWe developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin-biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits.
resultsDetection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25-40 μg/ml, 0.4-12.8 ng/ml, and 50-1600 pg/ml, respectively. The limit of detection of CRP, PCT, and IL-6 were 0.54 μg/ml, 0.11 ng/ml, and 16.25 pg/ml, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 min that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits.
conclusionsWMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of point-of-care testing (POCT). Therefore, WMC-MDP provides a promising alternative to POCT of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.