Evidence map›Paper›PMID 35144683›Full record

ArticleMilitary Medical Research2022

Wave-shaped microfluidic chip assisted point-of-care testing for accurate and rapid diagnosis of infections.

Bin-Feng Yin, Xin-Hua Wan, Ming-Zhu Yang, Chang-Cheng Qian, A S M Muhtasim Fuad Sohan

Open access · diamondAbstract read
In one paragraph

Article in Military Medical Research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 28 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Bin-Feng YinSchool of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, Jiangsu, China. binfengyin@yzu.edu.cn.ORCID 0000-0002-0484-4951
Xin-Hua WanSchool of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, Jiangsu, China.
Ming-Zhu YangDepartment of Biochemistry, Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences (CAMS) and Peking Union Medical College, Beijing, 100005, China.
Chang-Cheng QianSchool of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, Jiangsu, China.
A S M Muhtasim Fuad SohanSchool of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, Jiangsu, China.
Yangzhou University · CNChinese Academy of Medical Sciences & Peking Union Medical College · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEarly diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements.

methodsWe developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin-biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits.

resultsDetection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25-40 μg/ml, 0.4-12.8 ng/ml, and 50-1600 pg/ml, respectively. The limit of detection of CRP, PCT, and IL-6 were 0.54 μg/ml, 0.11 ng/ml, and 16.25 pg/ml, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 min that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits.

conclusionsWMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of point-of-care testing (POCT). Therefore, WMC-MDP provides a promising alternative to POCT of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.

Indexed as

MicrofluidicsPoint-of-Care TestingBiomarkersC-Reactive ProteinHumansPoint-of-Care SystemsBiomarkersC-Reactive ProteinChemiluminescenceInfection markersMultiplex detectionPoint-of-care testing (POCT)Wave-shaped microfluidic chip

Identifiers

PMID35144683
PMCPMC8831027
OpenAlexW4220739341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.