Evidence map›Paper›PMID 35142226›Full record

ArticleJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists2023

Novel Self-expanding Shape-Memory Bioresorbable Peripheral Stent Displays Efficient Delivery, Accelerated Resorption, and Low Luminal Loss in a Porcine Model.

Leonid Glushchenko, Brad Hubbard, Nikita Sedush, Vladislav Shchepochkin, Artur Krupnin, Aidar Sharafeev

Open access · hybridAbstract read
In one paragraph

Article in Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Leonid GlushchenkoResotech Medical Solutions Corp, Delaware, USA.ORCID 0000-0001-7428-2264
Brad HubbardPathway Preclinical Services, Minneapolis, MN, USA.
Nikita SedushResotech Medical Solutions Corp, Delaware, USA.
Vladislav ShchepochkinResotech Medical Solutions Corp, Delaware, USA.
Artur KrupninResotech Medical Solutions Corp, Delaware, USA.ORCID 0000-0002-5674-4143
Aidar SharafeevResotech Medical Solutions Corp, Delaware, USA.
Pathways Behavioral Services · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

OBJECTIVE AND

designThe search for improved stenting technologies to treat peripheral artery disease is trending toward biodegradable self-expanding shape-memory stents that, as of now, still suffer from the acute trade-off between deliverability and luminal stability: Higher deliverability leads to lower lumen stability, vessel recoil, and stent breakage. This study was aimed at the development and testing of a self-expanding bioresorbable poly(l,l-lactide-co-ε-caprolactone) stent that was designed to produce confident self-expansion after efficient crimping, as well as quick bioresorption, and sufficient radial force. MATERIALS AND

methodsBench tests were employed to measure shape-memory properties, radial force, and hydrolytic degradation of the stent. The porcine model was employed to study deliverability, lumen stability, biocompatibility, and stent integrity. A total of 32 stents were implanted in the iliac arteries of 16 pigs with 15 to 180 day follow-up periods. The stented vessels were studied by angiography and histological evaluation.

resultsRecovery of the diameter of the stent due to shape-memory effect was equal to 90.6% after 6Fr crimping and storage in refrigeration for 1 week. Radial force measured after storage was equal to 0.7 N/mm. Technical success of implantation in pigs (after the delivery implemented by pusher) was 94%. At 180 days, no implanted stents were found to be fragmented: All of the devices remained at the site of implantation with no stent migration and all stents retained their luminal support. Only moderate inflammation and neoepithelialization were detected by histological assessment at 60, 90, 120, and 180 days. Lumen loss at 180 days was less than 25% of the vessel diameter.

conclusionsThe stent with the mechanical and chemical properties described in this study may present the optimal solution of the trade-off between deliverability and luminal stability that is necessary for designing the next generation stent for endovascular therapy of peripheral arterial disease.

Indexed as

Absorbable ImplantsStentsAngiographyAnimalsSwineTreatment OutcomeVascular Patencybioresorptionperipheral scaffoldself-expanding stentshape memory

Identifiers

PMID35142226
PMCPMC9896407
OpenAlexW4211239872

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked