Evidence map›Paper›PMID 35141649›Full record

ArticleNorth American Spine Society journal2021

Operator independent reliability of direct augmented reality navigated pedicle screw placement and rod bending.

Mazda Farshad, José Miguel Spirig, Daniel Suter, Armando Hoch, Marco D Burkhard, Florentin Liebmann, Nadja A Farshad-Amacker, Philipp Fürnstahl

Open access · goldAbstract read
In one paragraph

Article in North American Spine Society journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 2 pooled it
4.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.

  1. Accuracy of augmented reality-assisted pedicle screw placement: a systematic review.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024
    Pooled it
  2. Pooled it
  3. An Optical Tracking-Based Robot-Assisted System for Spinal Fixation Rod Bending.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Factors affecting augmented reality head-mounted device performance in real OR.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Mazda FarshadUniversity Spine Center Zürich, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
José Miguel SpirigUniversity Spine Center Zürich, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
Daniel SuterUniversity Spine Center Zürich, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
Armando HochROCS: Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
Marco D BurkhardUniversity Spine Center Zürich, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
Florentin LiebmannUniversity Spine Center Zürich, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
Nadja A Farshad-AmackerRadiology, Balgrist University Hospital, University of Zürich, Forchstrasse 340, 8008 Zürich.
Philipp FürnstahlROCS: Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
University of Zurich · CHUniversitätsklinik Balgrist · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAR based navigation of spine surgeries may not only provide accurate surgical execution but also operator independency by compensating for potential skill deficits. "Direct" AR-navigation, namely superposing trajectories on anatomy directly, have not been investigated regarding their accuracy and operator's dependence.Purpose of this study was to prove operator independent reliability and accuracy of both AR assisted pedicle screw navigation and AR assisted rod bending in a cadaver setting.

methodsTwo experienced spine surgeons and two biomedical engineers (laymen) performed independently from each other pedicle screw instrumentations from L1-L5 in a total of eight lumbar cadaver specimens (20 screws/operator) using a fluoroscopy-free AR based navigation method. Screw fitting rods from L1 to S2-Ala-Ileum were bent bilaterally using an AR based rod bending navigation method (4 rods/operator). Outcome measures were pedicle perforations, accuracy compared to preoperative plan, registration time, navigation time, total rod bending time and operator's satisfaction for these procedures.

results97.5% of all screws were safely placed (<2 mm perforation), overall mean deviation from planned trajectory was 6.8±3.9°, deviation from planned entry point was 4±2.7 mm, registration time per vertebra was 2:25 min (00:56 to 10:00 min), navigation time per screw was 1:07 min (00:15 to 12:43 min) rod bending time per rod was 4:22 min (02:07 to 10:39 min), operator's satisfaction with AR based screw and rod navigation was 5.38±0.67 (1 to 6, 6 being the best rate). Comparison of surgeons and laymen revealed significant difference in navigation time (1:01 min; 00:15 to 3:00 min vs. 01:37 min; 00:23 to 12:43 min;

conclusionsDirect AR based screw and rod navigation using a surface digitization registration technique is reliable and independent of surgical experience. The accuracy of pedicle screw insertion in the lumbar spine is comparable with the current standard techniques.

Indexed as

AR, Augmented RealityAugmented realityCT, Computer TomographyHoloLensnDD, navigated Direction Deviation or navigated Trajectory DeviationnED, navigated Entry Point DeviationpDD, performed Direction Deviation or performed Trajectory Deviationpedicle screw accuracypedicle screw navigationpED, performed Entry Point DeviationRMSE, Root Mean Square Errorrod bendingvs., versus

Identifiers

PMID35141649
PMCPMC8819958
OpenAlexW3203144985

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.