ArticleScientific reports2022
Parametric investigation of an injection-jet self-powered Fontan circulation.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 21 citations in OpenAlex.
- A Translational Paradigm for Univentricular Heart Disease: Single-Stage Neonatal Repair with Adaptive Control of Cavopulmonary Flow.Cardiovascular engineering and technology · 2026Article
- In Vitro and In Silico Analysis of Entrainment Characterization in Injection Jet-Assisted Fontan Circulation.Bioengineering (Basel, Switzerland) · 2025Article
- Pediatric Cardiovascular Multiscale Modeling using a Functional Mock-up Interface.Cardiovascular engineering and technology · 2025Article
- Fontan Surgical Planning: Numerical Simulations Reveal Efficient Geometries Predicting Post-Surgical Outcomes.Brazilian journal of cardiovascular surgery · 2025Article
- The impact of blood viscosity modeling on computational fluid dynamic simulations of pediatric patients with Fontan circulation.Physics of fluids (Woodbury, N.Y. : 1994) · 2024Article
- Autonomous Fontan pump: Computational feasibility study.JTCVS open · 2024Article
- In vitro hemodynamic performance of a blood pump for self-powered venous assist in univentricular hearts.Scientific reports · 2024Article
- Switching the Left and the Right Hearts: A Novel Bi-ventricle Mechanical Support Strategy with Spared Native Single-Ventricle.Annals of biomedical engineering · 2023Article
- In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients.Cardiovascular engineering and technology · 2023Article
- Narrative review of single ventricle: where are we after 40 years?Translational pediatrics · 2023Review
- A computational study of aortic reconstruction in single ventricle patients.Biomechanics and modeling in mechanobiology · 2023Article
- In-Silico and In-Vitro Analysis of the Novel Hybrid Comprehensive Stage II Operation for Single Ventricle Circulation.Bioengineering (Basel, Switzerland) · 2023Article
- Characterization of baseline hemodynamics after the Fontan procedure: a retrospective cohort study on the comparison of 4D Flow MRI and computational fluid dynamics.Frontiers in physiology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Approximately [Formula: see text] babies are born with only one functioning ventricle and the Fontan is the third and, ideally final staged palliative operation for these patients. This altered circulation is prone to failure with survival rates below [Formula: see text] into adulthood. Chronically elevated inferior vena cava (IVC) pressure is implicated as one cause of the mortality and morbidity in this population. An injection jet shunt (IJS) drawing blood-flow directly from the aortic arch to significantly lower IVC pressure is proposed. A computer-generated 3D model of a 2-4 year old patient with a fenestrated Fontan and a cardiac output of 2.3 L/min was generated. The detailed 3D pulsatile hemodynamics are resolved in a zero-dimensional lumped parameter network tightly-coupled to a 3D computational fluid dynamics model accounting for non-Newtonian blood rheology and resolving turbulence using large eddy simulation. IVC pressure and systemic oxygen saturation were tracked for various IJS-assisted Fontan configurations, altering design parameters such as shunt and fenestration diameters and locations. A baseline "failing" Fontan with a 4 mm fenestration was tuned to have an elevated IVC pressure (+ 17.8 mmHg). Enlargement of the fenestration to 8 mm resulted in a 3 mmHg IVC pressure drop but an unacceptable reduction in systemic oxygen saturation below 80%. Addition of an IJS with a 2 mm nozzle and minor volume load to the ventricle improved the IVC pressure drop to 3.2 mmHg while increasing systemic oxygen saturation above 80%. The salutary effects of the IJS to effectively lower IVC pressure while retaining acceptable levels of oxygen saturation are successfully demonstrated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.